Home > Catalogue > Magnetic Components > Current Transformers (CT)

Current Transformers (CT)

Results:
Current Transformers (CT) Results:
Filter Results: -1/1882
Comprehensive
Price Priority
Stock Priority
Image
Part Number
Manufacturer
Description
Availability
Unit Price
Quantity
Operation
CTSCM40-200/5
HOBUT
HOBUT Current Transformers, CTSCMseries, turns_ratio 200:5, Clamp mounting type
Quantity: 6
Ship Date: 6-12 working days
1+ $61.1046
5+ $58.7273
10+ $56.9603
20+ $55.825
- +
x $61.1046
Ext. Price: $61.10
MOQ: 1
Mult: 1
SCS-4-4-40T-TR
Bel Fuse
40:1 7A 132μH 50KHz~1MHz SMD mount 4.7mm*3.65mm*3.55mm
Quantity: 1982
Ship Date: 7-12 working days
1+ $3.8016
10+ $3.4376
25+ $3.1778
50+ $3.0805
100+ $2.9856
250+ $2.8641
500+ $2.7749
1000+ $2.6881
- +
x $3.8016
Ext. Price: $3.80
MOQ: 1
Mult: 1
SPQ: 1
XM02-185071S000000
Sifam Tinsley
Sifam Tinsley Current Transformers, Omega XMERseries, turns_ratio 100:5, Base mounted type
Quantity: 5
Ship Date: 7-13 working days
1+ $18.3759
- +
x $18.3759
Ext. Price: $36.75
MOQ: 2
Mult: 1
1718832
RS
RS PRO Current Transformers, 400A, 5 Aoutput, turns_ratio 400:5, Base mounted type, Used forMCCB
Quantity: 2
Ship Date: 7-13 working days
1+ $42.1926
5+ $26.6681
- +
x $42.1926
Ext. Price: $42.19
MOQ: 1
Mult: 1
HTFS 200-P/SP2
LEM
300:1 ±300A 300:1 PCBinstall,board mount 40mm(width)*46.3mm(height)
Quantity: 84
Ship Date: 3-12 working days
1+ $22.3249
10+ $21.9262
25+ $21.9262
50+ $21.5276
100+ $21.5276
500+ $21.5276
1000+ $21.5276
- +
x $22.3249
Ext. Price: $22.32
MOQ: 1
Mult: 1
90.P3.25.000.0
LEM
LEM Current Transformers, LPSRseries, 50A, turns_ratio 50:1
Quantity: 3
Ship Date: 7-13 working days
1+ $20.5404
- +
x $20.5404
Ext. Price: $41.08
MOQ: 2
Mult: 1
XM19-365141S000000
Sifam Tinsley
Sifam Tinsley Current Transformers, Omega XMERseries, turns_ratio 750:5, Base mounted type
Quantity: 4
Ship Date: 7-13 working days
1+ $40.7042
- +
x $40.7042
Ext. Price: $40.70
MOQ: 1
Mult: 1
B82801C2245A200
TDK
1:200 40A 22.4mH 50KHz~500KHz SMD mount 14.22mm*13.46mm*10mm
Quantity: 22000
Ship Date: 8-16 working days
200+ $1.4122
600+ $1.3999
- +
x $1.4122
Ext. Price: $282.44
MOQ: 200
Mult: 200
SPQ: 200
30186180
LEM
Current Transducer HO 100-P-0100
Quantity: 108
Ship Date: 7-13 working days
1+ $23.7361
- +
x $23.7361
Ext. Price: $47.47
MOQ: 2
Mult: 1
LTS 25-NP
LEM
80:1 0mA~80A Through hole mounting 22.2mm(width)*24mm(height)
Quantity: 13248
Ship Date: 10-15 working days
1+ $19.3217
- +
x $19.3217
Ext. Price: $57.96
MOQ: 3
Mult: 1
SPQ: 50
LPSR 25-NP
LEM
Quantity: 1786
Ship Date: 10-15 working days
1+ $12.4006
- +
x $12.4006
Ext. Price: $62.00
MOQ: 5
Mult: 1
SPQ: 50
AP 50 B10
LEM
LEM Current Transformers, APseries, 50A, turns_ratio 50:1
Quantity: 25
Ship Date: 3-12 working days
1+ $117.7984
5+ $117.7984
10+ $115.6566
25+ $115.6566
50+ $115.6566
100+ $115.6566
- +
x $117.7984
Ext. Price: $117.79
MOQ: 1
Mult: 1
MR-4
KEMET
KEMET Current Transformers, MRseries, 125A
Quantity: 155
Ship Date: 6-13 working days
1+ $15.065
5+ $13.563
10+ $13.0248
25+ $12.7872
50+ $12.7008
100+ $12.312
500+ $11.9385
- +
x $15.065
Ext. Price: $15.06
MOQ: 1
Mult: 1
SPQ: 1
T60404-N4644-X271
VACUUMSCHMELZE
200A DC~100KHz 41mm(length)*33.4mm(height)
Quantity: 178
Ship Date: 6-13 working days
1+ $50.16
5+ $41.5368
10+ $38.5992
25+ $35.046
60+ $31.6575
120+ $30.198
- +
x $50.16
Ext. Price: $50.16
MOQ: 1
Mult: 1
SPQ: 1
192T2034
SOCOMEC
Current Transformers, TCA 22series, 400A, 5 Aoutput, turns_ratio 400:5A,
Quantity: 1
Ship Date: 7-13 working days
1+ $55.8192
- +
x $55.8192
Ext. Price: $55.81
MOQ: 1
Mult: 1
192T4715
SOCOMEC
1500:5 155mm(width)*198mm(height)
Quantity: 6
Ship Date: 5-10 working days
1+ $446.0846
- +
x $446.0846
Ext. Price: $446.08
MOQ: 1
Mult: 1
49506050
SOCOMEC
Closed toroid type A 50mm 85A DELTA IC50
Quantity: 1
Ship Date: 5-10 working days
1+ $136.0625
- +
x $136.0625
Ext. Price: $136.06
MOQ: 1
Mult: 1
MR-3
KEMET
10A 50Hz,60Hz 30Ω wire mounting,base mount 30.5mm*28mm*10.5mm
Quantity: 393
Ship Date: 6-13 working days
1+ $13.386
5+ $11.825
10+ $11.2536
25+ $10.8324
50+ $10.5192
- +
x $13.386
Ext. Price: $13.38
MOQ: 1
Mult: 1
SPQ: 1
CST206-3T
Triad Magnetics
70A 130mH 20KHz~200KHz 6KVμs 12.4Ω 300:1 Plugins Through hole mounting 27.31mm*10.16mm*31.12mm
Quantity: 238
Ship Date: 6-13 working days
1+ $5.681
50+ $5.2488
100+ $4.7952
252+ $4.6008
504+ $4.3575
1008+ $4.242
- +
x $5.681
Ext. Price: $5.68
MOQ: 1
Mult: 1
SPQ: 1
CST306-2T
Triad Magnetics
25A 14mH 20KHz~200KHz 1KVμs 1.55Ω 100CT:1 Plugins Through hole mounting 17.53mm*9.78mm*23.24mm
Quantity: 101
Ship Date: 6-13 working days
1+ $5.129
10+ $4.829
25+ $4.5684
50+ $4.4172
100+ $4.104
252+ $3.888
504+ $3.654
- +
x $5.129
Ext. Price: $5.12
MOQ: 1
Mult: 1
SPQ: 1
AC1050
talema
50A 50Hz,60Hz 49.3Ω 1000:1 Plugins Through hole mounting 34.9mm*14.3mm*34.9mm
Quantity: 10131
Ship Date: 14-18 working days
5+ $3.7709
25+ $2.9928
100+ $2.5888
200+ $2.4391
- +
x $3.7709
Ext. Price: $33.93
MOQ: 9
Mult: 1
SPQ: 1
CT75A
Hammond Manufacturing
5A 75:5 wire mounting,base mount 95.25mm*44.45mm*82.55mm
Quantity: 2
Ship Date: 6-13 working days
1+ $76.571
10+ $68.8716
25+ $64.2915
50+ $63.3675
100+ $62.412
- +
x $76.571
Ext. Price: $76.57
MOQ: 1
Mult: 1
SPQ: 1
XS02-335085S 000000
Sifam Tinsley
Sifam Tinsley Current Transformers, Omega10series, turns_ratio 600:5, Clamp mounting type
Quantity: 18
Ship Date: 7-13 working days
1+ $61.0784
- +
x $61.0784
Ext. Price: $61.07
MOQ: 1
Mult: 1
XM02-225071S000000
Sifam Tinsley
Sifam Tinsley Current Transformers, Omega XMERseries, turns_ratio 150:5, Base mounted type
Quantity: 1
Ship Date: 5-10 working days
1+ $13.7913
5+ $13.2396
10+ $12.688
- +
x $13.7913
Ext. Price: $13.79
MOQ: 1
Mult: 1
ECSTA1V0504-1050-R
EATON
50:1 7A 205μH 50KHz~1MHz SMD mount 4.8mm*3.65mm*3.55mm
Quantity: 1
Ship Date: 6-12 working days
1+ $3.8485
- +
x $3.8485
Ext. Price: $7.69
MOQ: 2
Mult: 1

Current Transformers (CT)

Current Transformers (CTs) are devices used in electrical power systems to convert high alternating current (AC) to a lower, safer level for measurement and protection purposes. They are essential components in power distribution and control systems.

Definition:
A current transformer is an instrument transformer designed to provide a current that is proportional to the current in a primary circuit. It typically consists of a toroidal core with a primary winding and a secondary winding. The primary winding is connected in series with the load, while the secondary winding is connected to the measuring or protective devices.

Function:
1. Measurement: CTs allow for the accurate measurement of current in high-voltage circuits without the need for high-voltage-rated meters or protection relays.
2. Protection: They are used in conjunction with relays to provide overcurrent, short-circuit, and earth-fault protection in power systems.
3. Control: CTs enable the control of power flow in circuits by providing feedback to control systems.

Applications:
1. Power Distribution: In substations and distribution boards to monitor and control the flow of electricity.
2. Metering: For billing purposes in utility companies to measure the amount of electricity consumed by customers.
3. Protection Systems: To detect faults and initiate circuit breakers to prevent damage to the electrical infrastructure.

Selection Criteria:
1. Rated Current: The CT should be rated for the maximum current expected in the primary circuit.
2. Accuracy Class: Depending on the application, CTs are classified by their accuracy (e.g., 0.5, 0.2, 0.1 class).
3. Turns Ratio: The ratio of primary to secondary turns determines the current transformation ratio.
4. Insulation Level: Must be suitable for the voltage level of the primary circuit.
5. Environmental Conditions: CTs must be rated for the environmental conditions they will be exposed to, such as temperature, humidity, and pollution levels.
6. Size and Physical Characteristics: The physical size and shape of the CT must be compatible with the installation location and the equipment it is connected to.

In summary, current transformers are vital for the safe and efficient operation of electrical systems, providing a means to measure, control, and protect against electrical faults in high-current applications. Their selection should be based on the specific requirements of the system they will be used in.
Please refer to the product rule book for details.