Home > Catalogue > Magnetic Components > Current Transformers (CT)

Current Transformers (CT)

Results:
Current Transformers (CT) Results:
Filter Results: -1/1996
Comprehensive
Price Priority
Stock Priority
Image
Part Number
Manufacturer
Description
Availability
Unit Price
Quantity
Operation
ACS72981KLRATR-150B3
Allegro MicroSystems
Current Sensor AC/DC Current 3.3V T/R
Quantity: 6000
Ship Date: 7-12 working days
3000+ $2.7577
- +
x $2.7577
Ext. Price: $8273.10
MOQ: 3000
Mult: 3000
DK 400 B420
LEM
400:1 400A 400:1 panel mount 89.7mm(width)*57.2mm(height)
Quantity: 9
Ship Date: 7-13 working days
1+ $526.7593
- +
x $526.7593
Ext. Price: $526.75
MOQ: 1
Mult: 1
B82801A1185A150
TDK
1:150 1.84mH 50KHz~1MHz 43.2Vμs SMD mount 4.7mm*3.5mm*3.5mm
Quantity: 177
Ship Date: 7-12 working days
1+ $3.1752
10+ $2.6114
25+ $2.3263
50+ $2.1934
100+ $2.068
250+ $1.979
- +
x $3.1752
Ext. Price: $3.17
MOQ: 1
Mult: 1
SPQ: 1
ACS710KLATR-6BB-NL-T
Allegro MicroSystems
Current Sensor Current Sensor AC/DC Current 3.3V/5V 16-Pin SOIC W T/R
Quantity: 1000
Ship Date: 7-12 working days
1000+ $3.156
2000+ $3.0637
3000+ $3.0133
- +
x $3.156
Ext. Price: $3156.00
MOQ: 1000
Mult: 1000
SPQ: 1
PACT MCR-V2-6015- 85- 400-5A-1
PHOENIX CONTACT
Current transformer
Quantity: 17
Ship Date: 7-13 working days
1+ $64.4788
- +
x $64.4788
Ext. Price: $64.47
MOQ: 1
Mult: 1
PACT MCR-V2-6015- 85- 800-5A-1
PHOENIX CONTACT
Current transformer
Quantity: 9
Ship Date: 7-13 working days
1+ $62.3988
- +
x $62.3988
Ext. Price: $62.39
MOQ: 1
Mult: 1
SCS-40320
Bel Fuse
40:1 10A 320μH 50KHz~1MHz SMD mount 5.5mm(height)
Quantity: 991
Ship Date: 7-12 working days
1+ $3.523
10+ $2.6438
25+ $2.4448
50+ $2.3706
100+ $2.2981
250+ $2.2049
500+ $2.1366
- +
x $3.523
Ext. Price: $3.52
MOQ: 1
Mult: 1
SPQ: 1
SCS-8-3-200T-TR
Bel Fuse
200:1 15A 22mH 50KHz~1MHz SMD mount 13mm*11mm*7.8mm
Quantity: 350
Ship Date: 7-12 working days
350+ $4.9304
- +
x $4.9304
Ext. Price: $1725.64
MOQ: 350
Mult: 350
SPQ: 1
CTRA8120/5-2.5/1-1809
HOBUT
HOBUT Current Transformers, CTRAseries, Used for5A
Quantity: 9
Ship Date: 7-13 working days
1+ $28.485
- +
x $28.485
Ext. Price: $28.48
MOQ: 1
Mult: 1
CT160-5-K7
HOBUT
16 Series (160) wound primary 30/5 5VA
Quantity: 4
Ship Date: 7-13 working days
1+ $39.7612
5+ $29.3134
10+ $28.0942
- +
x $39.7612
Ext. Price: $39.76
MOQ: 1
Mult: 1
CT173M120/5-2.5/1-002
HOBUT
HOBUT Current Transformers, CT173series, 120A, 5 Aoutput, turns_ratio 120:5, Base mounted type
Quantity: 11
Ship Date: 7-13 working days
1+ $24.1556
- +
x $24.1556
Ext. Price: $48.31
MOQ: 2
Mult: 1
AP 50 B420L
LEM
50:1 50A 50:1 DINRail installation 67mm(width)*69mm(height)
Quantity: 48
Ship Date: 3-12 working days
1+ $128.7058
5+ $128.7058
10+ $126.3658
25+ $126.3658
50+ $126.3658
- +
x $128.7058
Ext. Price: $128.70
MOQ: 1
Mult: 1
90.O9.09.000.0
LEM
LEM Current Transformers, LXSseries, 6A, turns_ratio 6:1
Quantity: 34
Ship Date: 7-13 working days
1+ $24.555
- +
x $24.555
Ext. Price: $49.11
MOQ: 2
Mult: 1
XN35-245031S000000
Sifam Tinsley
Sifam Tinsley Current Transformers, Omegaseries, 200A, 5 Aoutput, turns_ratio 200:5, Base mounted type, Used forMCCB
Quantity: 2
Ship Date: 7-13 working days
1+ $39.726
- +
x $39.726
Ext. Price: $39.72
MOQ: 1
Mult: 1
XN25-235031S000000
Sifam Tinsley
Sifam Tinsley Current Transformers, Omegaseries, 160A, 5 Aoutput, turns_ratio 160:5, Base mounted type, Used forMCCB
Quantity: 3
Ship Date: 7-13 working days
1+ $53.7635
- +
x $53.7635
Ext. Price: $53.76
MOQ: 1
Mult: 1
CT-0050-D10
Littelfuse
50A 50:5 wire mounting,free hanging,Through hole mounting 62.5mm(length)
Quantity: 33
Ship Date: 7-12 working days
1+ $80.4128
10+ $72.2706
25+ $69.2428
50+ $67.0301
100+ $64.8832
- +
x $80.4128
Ext. Price: $80.41
MOQ: 1
Mult: 1
SPQ: 1
055656
BOURNS
864mH 10KHz~300KHz 2.14KVμs 13.5Ω Through hole mounting 27mm*18mm*17.5mm
Quantity: 120
Ship Date: 8-13 working days
1+ $5.4367
- +
x $5.4367
Ext. Price: $70.67
MOQ: 13
Mult: 1
CR2550-G
CR MAGNETICS
50Hz~400Hz wire mounting,free hanging,Through hole mounting 27.8mm(length)*22mm(width)
Quantity: 33
Ship Date: 7-12 working days
1+ $17.888
10+ $16.1127
25+ $15.4498
50+ $14.9644
100+ $14.4922
250+ $13.8883
500+ $13.4467
- +
x $17.888
Ext. Price: $17.88
MOQ: 1
Mult: 1
SPQ: 1
HLSR 20-SM
LEM
Current Sensors, 20A, Voltage output, 5VDC;
Quantity: 261
Ship Date: 3-12 working days
1+ $9.7317
10+ $9.0829
25+ $8.9207
50+ $8.9207
100+ $8.7585
500+ $8.7585
1000+ $8.7585
- +
x $9.7317
Ext. Price: $9.73
MOQ: 1
Mult: 1
PE-51686NL
Pulse Electronics
20A 5mH 20KHz~200KHz 50:1 DIP Through hole mounting 17.01mm*9.9mm*20.32mm
Quantity: 836
Ship Date: 6-8 working days
1+ $1.0634
150+ $0.9516
300+ $0.8897
- +
x $1.0634
Ext. Price: $51.04
MOQ: 48
Mult: 1
SPQ: 1
PE-51718NL
Pulse Electronics
20A 20mH 20KHz~200KHz 100CT:1 Through hole mounting 17.01mm*9.9mm*20.32mm
Quantity: 360
Ship Date: 14-19 working days
120+ $2.6586
300+ $2.6082
540+ $2.4822
1020+ $2.3436
2520+ $2.3058
- +
x $2.6586
Ext. Price: $584.89
MOQ: 220
Mult: 10
SPQ: 1
FC-SCT4.2-1:50
FC
1:50,inductance205uH,rated_current7A
Quantity: 1376
In Stock
24+
1+ $0.8192
10+ $0.7486
30+ $0.7082
100+ $0.5988
300+ $0.5763
1000+ $0.565
- +
x $0.8192
Ext. Price: $0.81
MOQ: 1
Mult: 1
SPQ: 2000
FC-SCT5.0-1:50
FC
20A 1:50 SMD
Quantity: 995
In Stock
24+
1+ $0.3318
- +
x $0.3318
Ext. Price: $0.33
MOQ: 1
Mult: 1
SPQ: 1000
PE-51688NL
Pulse Electronics
20A 80mH 20KHz~200KHz 200:1 DIP Through hole mounting 17.01mm*9.9mm*20.32mm
Quantity: 1140
Ship Date: 6-8 working days
1+ $1.0567
100+ $0.9283
300+ $0.8589
- +
x $1.0567
Ext. Price: $50.72
MOQ: 48
Mult: 1
SPQ: 1
NCB-H0402P100TR200F
NIC Components
100mΩ 0402 SMD mount 1.1mm(length)*600μm(height)
Quantity: 10000
Ship Date: 9-11 working days
23+
10000+ $0.0088
30000+ $0.0084
50000+ $0.0083
100000+ $0.0081
200000+ $0.0079
- +
x $0.0088
Ext. Price: $176.00
MOQ: 20000
Mult: 10000
SPQ: 10000

Current Transformers (CT)

Current Transformers (CTs) are devices used in electrical power systems to convert high alternating current (AC) to a lower, safer level for measurement and protection purposes. They are essential components in power distribution and control systems.

Definition:
A current transformer is an instrument transformer designed to provide a current that is proportional to the current in a primary circuit. It typically consists of a toroidal core with a primary winding and a secondary winding. The primary winding is connected in series with the load, while the secondary winding is connected to the measuring or protective devices.

Function:
1. Measurement: CTs allow for the accurate measurement of current in high-voltage circuits without the need for high-voltage-rated meters or protection relays.
2. Protection: They are used in conjunction with relays to provide overcurrent, short-circuit, and earth-fault protection in power systems.
3. Control: CTs enable the control of power flow in circuits by providing feedback to control systems.

Applications:
1. Power Distribution: In substations and distribution boards to monitor and control the flow of electricity.
2. Metering: For billing purposes in utility companies to measure the amount of electricity consumed by customers.
3. Protection Systems: To detect faults and initiate circuit breakers to prevent damage to the electrical infrastructure.

Selection Criteria:
1. Rated Current: The CT should be rated for the maximum current expected in the primary circuit.
2. Accuracy Class: Depending on the application, CTs are classified by their accuracy (e.g., 0.5, 0.2, 0.1 class).
3. Turns Ratio: The ratio of primary to secondary turns determines the current transformation ratio.
4. Insulation Level: Must be suitable for the voltage level of the primary circuit.
5. Environmental Conditions: CTs must be rated for the environmental conditions they will be exposed to, such as temperature, humidity, and pollution levels.
6. Size and Physical Characteristics: The physical size and shape of the CT must be compatible with the installation location and the equipment it is connected to.

In summary, current transformers are vital for the safe and efficient operation of electrical systems, providing a means to measure, control, and protect against electrical faults in high-current applications. Their selection should be based on the specific requirements of the system they will be used in.
Please refer to the product rule book for details.