HDC housings and bases form the outer mechanical parts of heavy-duty connector assemblies. Cable-side hoods and equipment-side mounting bodies accommodate the specified inserts and mating arrangement.
Where each housing part sits
The outer parts of a heavy-duty connector support the installation and enclose the internal connection components. They do not determine the complete electrical configuration on their own: the insert, contacts and any modular frame form separate parts of the system.
Assembly side
Product role
Cable-side hood
Provides the body around the cable-side insert and the cable-entry arrangement. Entry direction and available internal space affect how the cable approaches the connection.
Equipment-side base
Attaches the mating assembly to the equipment boundary. Mounting position, opening and fastening details belong to the installation drawing.
Matching enclosure pair
Combines the corresponding bodies and locking arrangement. A common size label alone is not evidence of unrestricted interchangeability between systems.
The insert determines the internal connection
HDC plug-in modules and inserts carry the configured electrical interfaces inside these bodies. The housing must accommodate the specified insert or modular arrangement, including the installation space needed behind the contacts. Cable entry and internal termination space should be considered together.
Material, locking features and environmental declarations vary with the exact housing series and assembly. An enclosure rating should therefore be taken from the documented configuration and stated conditions, rather than assigned to every hood or base in the category.