Home > Catalogue > Circuit Protection > Gas Discharge Tubes (GDT)

Gas Discharge Tubes (GDT)

Results:
Gas Discharge Tubes (GDT) Results:
Filter Results: -1/3470
Comprehensive
Price Priority
Stock Priority
Image
Part Number
Manufacturer
Description
Availability
Unit Price
Quantity
Operation
SMD75XM
SURGING
2KA 1812
Quantity: 1056
In Stock
24+
1+ $0.0721
10+ $0.0594
30+ $0.0493
100+ $0.0408
300+ $0.0399
2500+ $0.038
- +
x $0.0721
Ext. Price: $0.07
MOQ: 1
Mult: 1
SPQ: 2500
GTCR38-231M-R10
Littelfuse
3 10KA no 230V Plugins Through hole mounting 10mm(length)*7.5mm(height)
Quantity: 1000
Ship Date: 7-12 working days
1000+ $1.1219
- +
x $1.1219
Ext. Price: $1121.90
MOQ: 1000
Mult: 1000
SPQ: 1
2057-47-BT1LF
BOURNS
2 5KA no 470V Plugins Through hole mounting 6mm(length)*5.5mm(height)
Quantity: 500
Ship Date: 7-12 working days
500+ $0.4204
1000+ $0.3876
1500+ $0.3695
2500+ $0.3479
3500+ $0.3342
5000+ $0.3203
12500+ $0.2937
- +
x $0.4204
Ext. Price: $210.20
MOQ: 500
Mult: 500
SPQ: 1
2035-15-BLF
BOURNS
2 5KA no 150V Plugins Through hole mounting 4mm(length)
Quantity: 1500
Ship Date: 5-12 working days
Within 5 years
100+ $0.6886
500+ $0.5897
1000+ $0.5261
2500+ $0.5237
5000+ $0.4327
7500+ $0.4305
10000+ $0.4284
15000+ $0.4262
- +
x $0.6886
Ext. Price: $68.86
MOQ: 100
Mult: 100
2049-07-BT1LF
BOURNS
2 15KA no 75V Plugins Through hole mounting 6mm(length)*8mm(height)
Quantity: 590
Ship Date: 3-12 working days
1+ $0.6852
50+ $0.6852
100+ $0.6139
250+ $0.6139
500+ $0.603
1000+ $0.603
- +
x $0.6852
Ext. Price: $10.96
MOQ: 16
Mult: 1
2RL075M-5-SN
BrightKing
5KA SMD
Quantity: 8000
Ship Date: 3-8 working days
800+ $0.0966
1600+ $0.095
4000+ $0.0925
- +
x $0.0966
Ext. Price: $77.28
MOQ: 800
Mult: 800
SPQ: 800
2095-350-BLF
BOURNS
2 5KA no 3.5KV Plugins Through hole mounting 8mm(length)*8mm(height)
Quantity: 18
Ship Date: 3-12 working days
1+ $1.2431
10+ $1.0499
50+ $1.0079
100+ $0.9407
200+ $0.9239
500+ $0.9239
- +
x $1.2431
Ext. Price: $13.67
MOQ: 11
Mult: 1
GTCA28-212M-R03
TE Connectivity
GDT
Quantity: 1302
Ship Date: 5-12 working days
10+ $3.795
50+ $3.3912
100+ $1.4472
250+ $0.8516
500+ $0.7592
1000+ $0.6683
2500+ $0.6284
- +
x $3.795
Ext. Price: $37.95
MOQ: 10
Mult: 10
GTCA26-101M-R05
TE Connectivity
2 5KA Through hole mounting 6.2mm(height)
Quantity: 1000
Ship Date: 5-12 working days
10+ $2.1505
50+ $1.947
100+ $0.836
250+ $0.4792
500+ $0.4289
1000+ $0.3878
2500+ $0.3582
- +
x $2.1505
Ext. Price: $43.01
MOQ: 20
Mult: 10
2022-60A
BOURNS
Well-Type Gas Tube Protectors
Quantity: 36
Ship Date: 5-12 working days
Within 2 years
5+ $9.453
50+ $6.21
100+ $5.523
300+ $5.292
500+ $5.0295
1000+ $4.62
2500+ $4.494
5000+ $4.473
- +
x $9.453
Ext. Price: $47.26
MOQ: 5
Mult: 5
2410-310-G-MSP-T
BOURNS
5 yes 400V Through hole mounting 42.17mm(length)*42.17mm(height)
Quantity: 47
Ship Date: 5-12 working days
5+ $9.729
25+ $6.3828
100+ $5.5545
300+ $5.3865
500+ $5.334
1000+ $5.2815
2500+ $5.229
5000+ $5.1765
- +
x $9.729
Ext. Price: $48.64
MOQ: 5
Mult: 5
GTCR36-151M-R10
Littelfuse
3 10KA no 150V Plugins Through hole mounting 9.2mm(length)*6mm(height)
Quantity: 410
Ship Date: 7-9 working days
150+ $0.7988
350+ $0.7452
- +
x $0.7988
Ext. Price: $119.82
MOQ: 150
Mult: 1
SPQ: 1
SL1021B500R
Littelfuse
3 20KA no 500V Plugins Through hole mounting 10.5mm(length)
Quantity: 600
Ship Date: 9-11 working days
24+
100+ $2.464
300+ $2.387
400+ $2.376
1000+ $2.354
1500+ $2.332
- +
x $2.464
Ext. Price: $246.40
MOQ: 100
Mult: 100
SPQ: 100
SG150
Littelfuse
2 2KA no 150V 1812 SMD mount 4.5mm(length)*3.2mm(height)
Quantity: 12000
Ship Date: 6-11 working days
25+
2000+ $0.798
4000+ $0.7684
- +
x $0.798
Ext. Price: $1596.00
MOQ: 2000
Mult: 2000
SPQ: 2000
3RL600M-5-S
YAGEO
3 5KA 600V SMD mount 5mm(length)
Quantity: 880
Ship Date: 7-12 working days
1+ $1.222
5+ $1.0166
10+ $0.7787
50+ $0.6461
100+ $0.5741
250+ $0.516
- +
x $1.222
Ext. Price: $1.22
MOQ: 1
Mult: 1
SPQ: 1
B88069X380S102
TDK
2 2.5KA no 270V~345V Plugins Through hole mounting
Quantity: 95
Ship Date: 7 working days
1+ $1.0359
100+ $0.8491
- +
x $1.0359
Ext. Price: $1.03
MOQ: 1
Mult: 1
SPQ: 1
2053-07-SM-RPLF
BOURNS
Bourns gas discharge tube, DC breakdown voltage75V, surface mount devices, Maximum surge current 5kA
Quantity: 6374
Ship Date: 3-12 working days
5+ $0.525
50+ $0.4846
250+ $0.4523
500+ $0.4442
1000+ $0.4442
2700+ $0.4442
- +
x $0.525
Ext. Price: $13.12
MOQ: 25
Mult: 5
B88069X660S102
TDK
Quantity: 1000
Ship Date: 7 working days
100+ $0.4952
- +
x $0.4952
Ext. Price: $49.52
MOQ: 100
Mult: 100
SPQ: 100
2057-09-BT1LF
BOURNS
2 5KA no 90V Plugins Through hole mounting 6mm(length)*5.5mm(height)
Quantity: 50
Ship Date: 3-12 working days
1+ $0.521
50+ $0.501
100+ $0.4809
250+ $0.4489
500+ $0.4408
1000+ $0.4408
- +
x $0.521
Ext. Price: $10.94
MOQ: 21
Mult: 1
SG200
Littelfuse
2 1KA no 200V 1812 SMD mount 4.5mm(length)*3.2mm(height)
Quantity: 70000
Ship Date: 5-7 working days
2000+ $0.5036
4000+ $0.4915
8000+ $0.4835
16000+ $0.4754
- +
x $0.5036
Ext. Price: $1007.20
MOQ: 2000
Mult: 2000
SPQ: 2000
GTCS28-750M-R20-2
Littelfuse
2 20KA no 75V SMD mount 6mm(length)
Quantity: 1000
Ship Date: 7-12 working days
500+ $1.3026
- +
x $1.3026
Ext. Price: $651.29
MOQ: 500
Mult: 500
SPQ: 1
CG32.0LTR
Littelfuse
2 5KA no 2KV Through hole mounting 6mm(length)
Quantity: 881
Ship Date: 6-12 working days
1+ $10.4757
- +
x $10.4757
Ext. Price: $31.42
MOQ: 3
Mult: 1
2049-09-BLF
BOURNS
Bourns gas discharge tube, DC breakdown voltage90V, axial, Maximum surge current 20kA
Quantity: 450
Ship Date: 10-15 working days
10+ $0.6257
130+ $0.612
250+ $0.5987
- +
x $0.6257
Ext. Price: $75.08
MOQ: 120
Mult: 10
2089-360-BLF
BOURNS
Bourns gas discharge tube, DC breakdown voltage3600V, axial, Maximum surge current 3kA
Quantity: 887
Ship Date: 7-13 working days
500+ $0.6962
1000+ $0.6363
2000+ $0.6264
- +
x $0.6962
Ext. Price: $348.10
MOQ: 500
Mult: 500
CG2145L
Littelfuse
2 20KA no 145V Through hole mounting 6.07mm(length)*8.1mm(height)
Quantity: 147300
Ship Date: 5-10 working days
200+ $1.1504
- +
x $1.1504
Ext. Price: $230.08
MOQ: 200
Mult: 100

Gas Discharge Tubes (GDT)

Gas Discharge Tubes (GDTs) are a type of overvoltage protection device that operates by using the ionization of gas to conduct electricity. They are designed to protect sensitive electronic equipment from voltage surges, which can be caused by lightning, power line switching, or other electrical disturbances.

Definition:
A Gas Discharge Tube is a passive electronic component that contains two or more electrodes within a gas-filled envelope. When the voltage across the GDT exceeds a certain threshold, the gas ionizes, creating a conductive path that allows the excess voltage to be safely discharged.

Function:
The primary function of a GDT is to clamp the voltage to a safe level by diverting the surge current away from the protected equipment. When the voltage across the GDT is below the ionization threshold, it acts as an open circuit, allowing normal operation of the equipment. Once the voltage exceeds the threshold, the GDT ionizes the gas, becoming a low-impedance path for the surge current to flow, thus protecting the equipment from damage.

Applications:
GDTs are widely used in various applications where overvoltage protection is necessary:
1. Telecommunications equipment, such as telephone exchanges and network infrastructure.
2. Power distribution systems to protect against lightning-induced surges.
3. Industrial control systems to safeguard against voltage spikes.
4. Consumer electronics, like televisions and computers, to protect against power surges.
5. Automotive electronics to protect against transient voltages.

Selection Criteria:
When selecting a GDT, several factors should be considered:
1. Voltage Rating: The GDT should have a continuous voltage rating that is compatible with the system's operating voltage.
2. Surge Current Capability: The GDT must be able to handle the expected surge current without failing.
3. Response Time: The GDT should have a fast response time to effectively protect against fast-rising surges.
4. Recovery Time: After discharging, the GDT should return to its non-conductive state quickly to minimize the impact on normal operation.
5. Physical Size and Mounting: The GDT should be compatible with the available space and mounting requirements of the equipment.
6. Environmental Considerations: The GDT should be suitable for the environmental conditions it will be exposed to, such as temperature and humidity.

In summary, Gas Discharge Tubes are crucial components in the protection of electronic systems from overvoltage events. They are selected based on their ability to handle the specific voltage and current requirements of the application, as well as their physical and environmental compatibility.
Please refer to the product rule book for details.