Home > Catalogue > Circuit Protection > Gas Discharge Tubes (GDT)

Gas Discharge Tubes (GDT)

Results:
Gas Discharge Tubes (GDT) Results:
Filter Results: -1/3630
Comprehensive
Price Priority
Stock Priority
Image
Part Number
Manufacturer
Description
Availability
Unit Price
Quantity
Operation
3RP150L-8/B
BrightKing
20KA
Quantity: 2000
Ship Date: 8-12 weeks
24+
500+ $0.2673
- +
x $0.2673
Ext. Price: $133.65
MOQ: 500
Mult: 500
SPQ: 100
2RP600M-8-S
BrightKing
Gas Discharge Tubs
Quantity: 2400
Ship Date: 3-8 working days
24+
600+ $0.1318
1200+ $0.1296
3000+ $0.1263
- +
x $0.1318
Ext. Price: $79.08
MOQ: 600
Mult: 600
SPQ: 600
4532-351-LF
YAGEO
Gas Discharge Tubs
Quantity: 292
Ship Date: 3-12 working days
5+ $0.3974
50+ $0.3357
250+ $0.3008
500+ $0.3008
1000+ $0.2954
2500+ $0.2954
- +
x $0.3974
Ext. Price: $11.92
MOQ: 30
Mult: 5
2RL2500L-8/B
YAGEO
2 5KA Plugins Through hole mounting
Quantity: 1500
Ship Date: 7-9 working days
250+ $0.4838
1100+ $0.4494
- +
x $0.4838
Ext. Price: $120.95
MOQ: 250
Mult: 1
SPQ: 1
B88069X0590S102
TDK
2 2.5KA no 350V Plugins Through hole mounting 6mm(length)
Quantity: 980
Ship Date: 6-13 working days
1+ $1.2995
10+ $1.196
50+ $0.9449
100+ $0.869
200+ $0.7506
500+ $0.7063
1000+ $0.6416
2500+ $0.6405
5000+ $0.545
- +
x $1.2995
Ext. Price: $1.29
MOQ: 1
Mult: 1
SPQ: 1
CG2230
Littelfuse
2 20KA no 230V welding mounting,SMD mount 6.07mm(length)
Quantity: 566
Ship Date: 6-13 working days
1+ $3.519
5+ $3.2085
10+ $2.97
50+ $1.518
1200+ $1.3965
- +
x $3.519
Ext. Price: $3.51
MOQ: 1
Mult: 1
SPQ: 1
2R230TD-8
RUILON
20KA Plugins,D8XL6MM Through hole mounting 6mm(length)*8mm(width)
Quantity: 59
In Stock
21+
1+ $0.1352
10+ $0.1295
50+ $0.1262
100+ $0.1216
- +
x $0.1352
Ext. Price: $0.13
MOQ: 1
Mult: 1
SPQ: 800
2027-60-SM-RP-LF
BOURNS
2 10KA no 600V SMD mount 6.4mm(length)*8mm(height)
Quantity: 1000
Ship Date: 5-12 working days
Within 1 year
500+ $0.7463
1000+ $0.6374
2500+ $0.5733
5000+ $0.5502
7500+ $0.5471
10000+ $0.545
15000+ $0.5418
25000+ $0.5397
- +
x $0.7463
Ext. Price: $373.15
MOQ: 500
Mult: 500
B88069X4241S102
TDK
2 100A no 3.6KV Through hole mounting 60mm(length)
Quantity: 1845
In Stock
2532+
1+ $0.3278
10+ $0.2764
30+ $0.243
100+ $0.2135
500+ $0.193
1000+ $0.1807
- +
x $0.3278
Ext. Price: $0.32
MOQ: 1
Mult: 1
SPQ: 100
SXH81-152X
SURGING
5KA Plugins,D8XL6MM
Quantity: 14
In Stock
23+
1+ $0.1121
10+ $0.1074
50+ $0.1047
100+ $0.1009
- +
x $0.1121
Ext. Price: $0.11
MOQ: 1
Mult: 1
SPQ: 500
3R230A-5S
RUILON
5KA SMD,5X7.5MM SMD mount 7.5mm(length)*5mm(width)
Quantity: 291
In Stock
21+
1+ $0.4307
10+ $0.342
30+ $0.3064
100+ $0.2544
300+ $0.2495
1000+ $0.2422
- +
x $0.4307
Ext. Price: $0.43
MOQ: 1
Mult: 1
SPQ: 1000
6-3R90
JKSEMI
Quantity: 1000
In Stock
23+
1+ $0.1327
- +
x $0.1327
Ext. Price: $0.13
MOQ: 1
Mult: 1
SPQ: 1000
3RL090L-6/B
BrightKing
Quantity: 2000
Ship Date: 8-12 weeks
24+
500+ $0.2025
- +
x $0.2025
Ext. Price: $101.25
MOQ: 500
Mult: 500
SPQ: 100
3RL075M-6
BrightKing
5KA SMD
Quantity: 12000
Ship Date: 8-12 weeks
24+
600+ $0.2281
1200+ $0.2243
3000+ $0.2187
- +
x $0.2281
Ext. Price: $136.86
MOQ: 600
Mult: 600
SPQ: 600
3RL090M-6
BrightKing
5KA SMD
Quantity: 12000
Ship Date: 8-12 weeks
24+
600+ $0.1943
1200+ $0.1912
3000+ $0.1863
- +
x $0.1943
Ext. Price: $116.58
MOQ: 600
Mult: 600
SPQ: 600
5-2R90
JKSEMI
5KA
Quantity: 1000
In Stock
23+
1+ $0.0863
- +
x $0.0863
Ext. Price: $0.08
MOQ: 1
Mult: 1
SPQ: 1000
CG31.5
Littelfuse
2 5KA no 1.5KV 6mm(length)
Quantity: 1163
Ship Date: 6-13 working days
1+ $4.5425
5+ $3.772
10+ $3.333
50+ $2.7108
100+ $2.5056
250+ $2.184
500+ $2.016
1200+ $1.8375
- +
x $4.5425
Ext. Price: $4.54
MOQ: 1
Mult: 1
SPQ: 1
SE60-90X
SURGING
6KA
Quantity: 1800
In Stock
25+
1+ $0.1658
10+ $0.1365
30+ $0.1133
100+ $0.0938
300+ $0.0917
2000+ $0.0873
- +
x $0.1658
Ext. Price: $0.16
MOQ: 1
Mult: 1
SPQ: 2000
GTCS35-401M-R05-2
Littelfuse
3 5KA no 400V SMD mount 7.6mm(length)
Quantity: 4654
Ship Date: 6-13 working days
1+ $2.2425
50+ $2.079
100+ $1.7388
250+ $1.638
500+ $1.3965
1000+ $1.2915
2000+ $0.902
- +
x $2.2425
Ext. Price: $2.24
MOQ: 1
Mult: 1
SPQ: 1
2089-200-BLF
BOURNS
2 1.5KA no 2KV Through hole mounting 6mm(length)*5.5mm(height)
Quantity: 1902
Ship Date: 6-13 working days
1+ $1.242
10+ $1.142
50+ $0.8415
100+ $0.8107
250+ $0.7063
500+ $0.6772
1000+ $0.5765
5000+ $0.503
- +
x $1.242
Ext. Price: $1.24
MOQ: 1
Mult: 1
SPQ: 1
CG6230SM
Littelfuse
2 3KA no 230V SMD mount 3.5mm(length)*4mm(height)
Quantity: 1955
Ship Date: 6-13 working days
1+ $2.7945
5+ $2.3575
10+ $2.185
50+ $1.738
100+ $1.5552
250+ $1.404
500+ $1.2495
1000+ $1.155
2000+ $1.071
- +
x $2.7945
Ext. Price: $2.79
MOQ: 1
Mult: 1
SPQ: 1
2RM090L-8/B
BrightKing
2,Lead
Quantity: 682
Ship Date: 3-8 working days
24+
500+ $0.1036
- +
x $0.1036
Ext. Price: $51.80
MOQ: 500
Mult: 500
SPQ: 100
4532-501-LF
BrightKing
2KA SMD,4.5X3.2MM
Quantity: 5000
Ship Date: 3-8 working days
24+
2500+ $0.0642
5000+ $0.0631
12500+ $0.0615
- +
x $0.0642
Ext. Price: $160.50
MOQ: 2500
Mult: 2500
SPQ: 2500
2RL090M-5-SST4.2
BrightKing
2,SMD
Quantity: 16000
Ship Date: 8-12 weeks
24+
800+ $0.0963
1600+ $0.0947
4000+ $0.0923
- +
x $0.0963
Ext. Price: $77.04
MOQ: 800
Mult: 800
SPQ: 800
2RM1000M-8-S
BrightKing
10KA
Quantity: 12000
Ship Date: 8-12 weeks
24+
600+ $0.147
1200+ $0.1445
3000+ $0.1409
- +
x $0.147
Ext. Price: $88.20
MOQ: 600
Mult: 600
SPQ: 600

Gas Discharge Tubes (GDT)

Gas Discharge Tubes (GDTs) are a type of overvoltage protection device that operates by using the ionization of gas to conduct electricity. They are designed to protect sensitive electronic equipment from voltage surges, which can be caused by lightning, power line switching, or other electrical disturbances.

Definition:
A Gas Discharge Tube is a passive electronic component that contains two or more electrodes within a gas-filled envelope. When the voltage across the GDT exceeds a certain threshold, the gas ionizes, creating a conductive path that allows the excess voltage to be safely discharged.

Function:
The primary function of a GDT is to clamp the voltage to a safe level by diverting the surge current away from the protected equipment. When the voltage across the GDT is below the ionization threshold, it acts as an open circuit, allowing normal operation of the equipment. Once the voltage exceeds the threshold, the GDT ionizes the gas, becoming a low-impedance path for the surge current to flow, thus protecting the equipment from damage.

Applications:
GDTs are widely used in various applications where overvoltage protection is necessary:
1. Telecommunications equipment, such as telephone exchanges and network infrastructure.
2. Power distribution systems to protect against lightning-induced surges.
3. Industrial control systems to safeguard against voltage spikes.
4. Consumer electronics, like televisions and computers, to protect against power surges.
5. Automotive electronics to protect against transient voltages.

Selection Criteria:
When selecting a GDT, several factors should be considered:
1. Voltage Rating: The GDT should have a continuous voltage rating that is compatible with the system's operating voltage.
2. Surge Current Capability: The GDT must be able to handle the expected surge current without failing.
3. Response Time: The GDT should have a fast response time to effectively protect against fast-rising surges.
4. Recovery Time: After discharging, the GDT should return to its non-conductive state quickly to minimize the impact on normal operation.
5. Physical Size and Mounting: The GDT should be compatible with the available space and mounting requirements of the equipment.
6. Environmental Considerations: The GDT should be suitable for the environmental conditions it will be exposed to, such as temperature and humidity.

In summary, Gas Discharge Tubes are crucial components in the protection of electronic systems from overvoltage events. They are selected based on their ability to handle the specific voltage and current requirements of the application, as well as their physical and environmental compatibility.
Please refer to the product rule book for details.