Home > Catalogue > Circuit Protection > Gas Discharge Tubes (GDT)

Gas Discharge Tubes (GDT)

Results:
Gas Discharge Tubes (GDT) Results:
Filter Results: -1/3630
Comprehensive
Price Priority
Stock Priority
Image
Part Number
Manufacturer
Description
Availability
Unit Price
Quantity
Operation
B88069X2180S102
TDK
EPCOS gas discharge tube, DC breakdown voltage1400V, Maximum surge current 15kA
Quantity: 335
Ship Date: 7 working days
100+ $1.2576
- +
x $1.2576
Ext. Price: $125.76
MOQ: 100
Mult: 100
SPQ: 100
B88069X2670T902
TDK
3 5KA no 357V~1.2KV SMD mount 7.6mm(length)
Quantity: 718
Ship Date: 6-13 working days
1+ $4.6575
5+ $4.3355
10+ $4.004
50+ $3.0888
100+ $2.5596
250+ $2.3835
500+ $2.058
900+ $1.911
1800+ $1.7535
- +
x $4.6575
Ext. Price: $4.65
MOQ: 1
Mult: 1
SPQ: 1
4532-091-LF-MS
MSKSEMI
2KA 1812
Quantity: 2500
Ship Date: 3-5 working days
24+
2500+ $0.0662
12500+ $0.0649
22500+ $0.0561
- +
x $0.0662
Ext. Price: $165.50
MOQ: 2500
Mult: 2500
SPQ: 2500
B88069X4870C103
TDK
2 10KA no 250V
Quantity: 990
Ship Date: 6-13 working days
1+ $2.0585
10+ $1.725
50+ $1.331
100+ $1.134
250+ $1.0778
500+ $0.9093
1000+ $0.6993
- +
x $2.0585
Ext. Price: $2.05
MOQ: 1
Mult: 1
SPQ: 1
2038-110-SMLF
BOURNS
3 5KA no 1.1KV SMD mount 7.3mm(length)*5mm(height)
Quantity: 1925
Ship Date: 6-13 working days
1+ $2.783
10+ $2.4265
50+ $1.87
100+ $1.5552
200+ $1.512
500+ $1.239
1000+ $1.134
2500+ $1.1025
- +
x $2.783
Ext. Price: $2.78
MOQ: 1
Mult: 1
SPQ: 1
2R090TA-5
RUILON
5KA Plugins,D5.5XL6MM Through hole mounting 5.5mm(length)*6mm(width)
Quantity: 100000
Ship Date: 2-4 weeks
24+
1000+ $0.1098
2000+ $0.108
4000+ $0.1052
6000+ $0.1034
16000+ $0.0961
- +
x $0.1098
Ext. Price: $109.80
MOQ: 1000
Mult: 1000
SPQ: 1000
2027-23-SM-LF
BOURNS
2 10KA no 230V SMD mount 6mm(length)*7.93mm(height)
Quantity: 515
Ship Date: 6-13 working days
1+ $1.2535
10+ $1.15
50+ $0.913
100+ $0.8426
250+ $0.7258
500+ $0.6653
1000+ $0.5975
2500+ $0.545
5000+ $0.5072
- +
x $1.2535
Ext. Price: $1.25
MOQ: 1
Mult: 1
SPQ: 1
2RF600L-8
FTR
20KA
Quantity: 100
Ship Date: 2-4 weeks
100+ $0.1063
300+ $0.1045
500+ $0.1017
13500+ $0.0952
- +
x $0.1063
Ext. Price: $10.63
MOQ: 100
Mult: 100
SPQ: 100
2052-42-SM-RPLF
BOURNS
Bourns gas discharge tube, DC breakdown voltage420V, surface mount devices, Maximum surge current 10kA
Quantity: 785
Ship Date: 6-13 working days
1+ $1.656
10+ $1.5295
50+ $1.21
100+ $1.1016
250+ $0.9828
500+ $0.8222
1000+ $0.7571
2700+ $0.756
- +
x $1.656
Ext. Price: $1.65
MOQ: 1
Mult: 1
SPQ: 1
2RL1000M-8-L5
BrightKing
5KA
Quantity: 4500
Ship Date: 5-7 working days
24+
500+ $0.1339
5000+ $0.1258
- +
x $0.1339
Ext. Price: $66.95
MOQ: 500
Mult: 500
SPQ: 500
SXH81-500X
SURGING
DIP,8*6
Quantity: 8000
Ship Date: 5-8 working days
24+
500+ $0.0822
1000+ $0.0809
1500+ $0.0788
- +
x $0.0822
Ext. Price: $41.10
MOQ: 500
Mult: 500
SPQ: 500
SXH81-400X
SURGING
DIP,8*6
Quantity: 8000
Ship Date: 5-8 working days
24+
500+ $0.0822
1000+ $0.0809
1500+ $0.0788
- +
x $0.0822
Ext. Price: $41.10
MOQ: 500
Mult: 500
SPQ: 500
B88069X7751B502
TDK
10KA
Quantity: 2750
Ship Date: 7 working days
100+ $0.3679
- +
x $0.3679
Ext. Price: $36.79
MOQ: 100
Mult: 100
SPQ: 100
B88069X4211T902
TDK
2 2.5KA no 300V SMD mount 4mm(length)
Quantity: 126000
Ship Date: 10-15 working days
1+ $3.8459
- +
x $3.8459
Ext. Price: $249.98
MOQ: 65
Mult: 1
B88069X2023B252
TDK
2 3KA Plugins Through hole mounting
Quantity: 442
Ship Date: 6-13 working days
1+ $3.0705
5+ $2.5645
10+ $2.254
50+ $1.848
100+ $1.7172
250+ $1.6065
500+ $1.386
1000+ $1.302
- +
x $3.0705
Ext. Price: $3.07
MOQ: 1
Mult: 1
SPQ: 1
B88069X9170B152
TDK
2 20KA no 800V Plugins threaded mounting,SMD mount 17.4mm(length)
Quantity: 147
Ship Date: 6-13 working days
1+ $32.67
5+ $26.5464
10+ $24.4728
50+ $19.677
100+ $17.346
300+ $16.3695
- +
x $32.67
Ext. Price: $32.67
MOQ: 1
Mult: 1
SPQ: 1
B88069X2963B161
TDK
GDT Stacked Surge Arresters in Casing
Quantity: 14
Ship Date: 6-13 working days
1+ $109.23
5+ $98.784
10+ $93.2925
48+ $76.839
- +
x $109.23
Ext. Price: $109.23
MOQ: 1
Mult: 1
SPQ: 1
B88069X7140B502
TDK
3 20KA yes 350V~550V Plugins Through hole mounting 10mm(length)
Quantity: 885
Ship Date: 6-13 working days
1+ $2.2425
10+ $2.07
50+ $1.639
100+ $1.4904
250+ $1.3392
500+ $1.1865
1000+ $1.176
- +
x $2.2425
Ext. Price: $2.24
MOQ: 1
Mult: 1
SPQ: 1
B88069X2213B252
TDK
2 3KA Plugins Through hole mounting
Quantity: 354
Ship Date: 6-13 working days
1+ $3.5075
5+ $2.9095
10+ $2.5185
50+ $2.101
100+ $1.9548
250+ $1.7535
500+ $1.5435
1000+ $1.4175
2500+ $1.3335
- +
x $3.5075
Ext. Price: $3.50
MOQ: 1
Mult: 1
SPQ: 1
B88069X2053B252
TDK
2 3KA Plugins Through hole mounting
Quantity: 30
Ship Date: 6-13 working days
1+ $2.875
10+ $2.553
50+ $2.013
100+ $1.7928
250+ $1.596
500+ $1.5225
1000+ $1.4175
5000+ $1.2285
- +
x $2.875
Ext. Price: $2.87
MOQ: 1
Mult: 1
SPQ: 1
B88069X9451T203
TDK
EPCOS gas discharge tube, DC breakdown voltage90V, surface mount devices, Maximum surge current 2kA
Quantity: 480
Ship Date: 7-9 working days
200+ $0.5375
- +
x $0.5375
Ext. Price: $107.50
MOQ: 200
Mult: 1
SPQ: 1
B88069X0800S102
TDK
2 2.5KA no 270V~345V Plugins Through hole mounting 6mm(length)
Quantity: 469
Ship Date: 6-13 working days
1+ $1.2765
10+ $1.173
50+ $0.9295
100+ $0.8558
200+ $0.7387
500+ $0.6955
1000+ $0.6237
2500+ $0.6174
5000+ $0.545
- +
x $1.2765
Ext. Price: $1.27
MOQ: 1
Mult: 1
SPQ: 1
B88069X5941T253
TDK
2KA SMD,4.5X3.2MM
Quantity: 4116
Ship Date: 6-13 working days
1+ $1.035
10+ $0.9488
50+ $0.7524
100+ $0.6941
250+ $0.6124
500+ $0.5648
1000+ $0.5061
2500+ $0.4337
5000+ $0.3969
- +
x $1.035
Ext. Price: $2.06
MOQ: 2
Mult: 1
SPQ: 1
BTC401N
BORN
2KA 1812
Quantity: 200000
Ship Date: 3-10 working days
25+
2500+ $0.0718
7500+ $0.0705
12500+ $0.0688
- +
x $0.0718
Ext. Price: $179.50
MOQ: 2500
Mult: 2500
SPQ: 2500
2047-09-ALF
BOURNS
2 50KA no 90V welding mounting,SMD mount 12.7mm(length)
Quantity: 140
Ship Date: 7-9 working days
30+ $4.2355
65+ $4.0442
100+ $3.7778
- +
x $4.2355
Ext. Price: $127.06
MOQ: 30
Mult: 1
SPQ: 1

Gas Discharge Tubes (GDT)

Gas Discharge Tubes (GDTs) are a type of overvoltage protection device that operates by using the ionization of gas to conduct electricity. They are designed to protect sensitive electronic equipment from voltage surges, which can be caused by lightning, power line switching, or other electrical disturbances.

Definition:
A Gas Discharge Tube is a passive electronic component that contains two or more electrodes within a gas-filled envelope. When the voltage across the GDT exceeds a certain threshold, the gas ionizes, creating a conductive path that allows the excess voltage to be safely discharged.

Function:
The primary function of a GDT is to clamp the voltage to a safe level by diverting the surge current away from the protected equipment. When the voltage across the GDT is below the ionization threshold, it acts as an open circuit, allowing normal operation of the equipment. Once the voltage exceeds the threshold, the GDT ionizes the gas, becoming a low-impedance path for the surge current to flow, thus protecting the equipment from damage.

Applications:
GDTs are widely used in various applications where overvoltage protection is necessary:
1. Telecommunications equipment, such as telephone exchanges and network infrastructure.
2. Power distribution systems to protect against lightning-induced surges.
3. Industrial control systems to safeguard against voltage spikes.
4. Consumer electronics, like televisions and computers, to protect against power surges.
5. Automotive electronics to protect against transient voltages.

Selection Criteria:
When selecting a GDT, several factors should be considered:
1. Voltage Rating: The GDT should have a continuous voltage rating that is compatible with the system's operating voltage.
2. Surge Current Capability: The GDT must be able to handle the expected surge current without failing.
3. Response Time: The GDT should have a fast response time to effectively protect against fast-rising surges.
4. Recovery Time: After discharging, the GDT should return to its non-conductive state quickly to minimize the impact on normal operation.
5. Physical Size and Mounting: The GDT should be compatible with the available space and mounting requirements of the equipment.
6. Environmental Considerations: The GDT should be suitable for the environmental conditions it will be exposed to, such as temperature and humidity.

In summary, Gas Discharge Tubes are crucial components in the protection of electronic systems from overvoltage events. They are selected based on their ability to handle the specific voltage and current requirements of the application, as well as their physical and environmental compatibility.
Please refer to the product rule book for details.