2045-40-BLF
BOURNS
Bourns gas discharge tube, DC breakdown voltage400V, axial, Maximum surge current 15kA
Quantity: 620
Ship Date: 6-13 working days
1+ $0.851
10+ $0.7797
50+ $0.6193
100+ $0.572
250+ $0.5044
500+ $0.4644
1000+ $0.3985
2500+ $0.3866
5000+ $0.3633
- +
x $0.851
Ext. Price: $1.70
MOQ: 2
Mult: 1
SPQ: 1
BK12018002-H
YAGEO
2 3KA Through hole mounting
Quantity: 1310
Ship Date: 6-13 working days
1+ $0.874
10+ $0.8039
50+ $0.638
100+ $0.5885
250+ $0.5195
500+ $0.4795
1000+ $0.4406
2000+ $0.4234
5000+ $0.3539
- +
x $0.874
Ext. Price: $1.74
MOQ: 2
Mult: 1
SPQ: 1
B88069X8671S102
TDK
2 2.7KV Through hole mounting 6mm(length)
Quantity: 541
Ship Date: 6-13 working days
1+ $2.323
10+ $1.978
50+ $1.529
100+ $1.2744
200+ $1.242
500+ $1.0606
1000+ $0.9774
2500+ $0.8337
- +
x $2.323
Ext. Price: $2.32
MOQ: 1
Mult: 1
SPQ: 1
2027-35-SM-RP-LF
BOURNS
2 10KA no 350V SMD mount 6.4mm(length)*8mm(height)
Quantity: 392
Ship Date: 6-13 working days
1+ $1.288
10+ $1.2075
50+ $1.0197
100+ $0.9547
250+ $0.8932
500+ $0.7279
1000+ $0.6394
2500+ $0.5628
5000+ $0.5387
- +
x $1.288
Ext. Price: $1.28
MOQ: 1
Mult: 1
SPQ: 1
2026-42-C2FLF
BOURNS
3 20KA yes 420V Plugins Through hole mounting
Quantity: 83
Ship Date: 6-13 working days
1+ $4.117
5+ $3.8065
10+ $3.509
50+ $2.7108
100+ $2.2572
300+ $2.1492
500+ $1.8684
1000+ $1.68
2500+ $1.533
- +
x $4.117
Ext. Price: $4.11
MOQ: 1
Mult: 1
SPQ: 1
2035-60-BLF
BOURNS
2 5KA no 600V Plugins Through hole mounting 4mm(length)
Quantity: 990
Ship Date: 6-13 working days
1+ $1.0925
10+ $1.0051
50+ $0.7986
100+ $0.7359
200+ $0.635
500+ $0.5983
1000+ $0.5638
2500+ $0.5345
5000+ $0.4431
- +
x $1.0925
Ext. Price: $2.18
MOQ: 2
Mult: 1
SPQ: 1
B88069X8860B502
TDK
3 20KA yes 250V Plugins Through hole mounting 13.4mm(length)
Quantity: 390
Ship Date: 6-13 working days
1+ $3.1855
10+ $2.7945
50+ $2.1168
100+ $1.8036
250+ $1.7496
500+ $1.4688
1000+ $1.242
5000+ $1.1865
- +
x $3.1855
Ext. Price: $3.18
MOQ: 1
Mult: 1
SPQ: 1
B88069X9801T253
TDK
Quantity: 1621
Ship Date: 6-13 working days
1+ $1.0695
10+ $0.8476
50+ $0.671
100+ $0.5962
250+ $0.5357
500+ $0.486
1000+ $0.4482
2500+ $0.405
- +
x $1.0695
Ext. Price: $2.13
MOQ: 2
Mult: 1
SPQ: 1
SL1411A600SM
Littelfuse
2 10KA no 600V SMD mount 6.05mm(length)*8mm(height)
Quantity: 380
Ship Date: 6-13 working days
1+ $2.875
5+ $2.6565
10+ $2.5185
50+ $1.9116
100+ $1.8576
500+ $1.4688
2500+ $1.3965
- +
x $2.875
Ext. Price: $2.87
MOQ: 1
Mult: 1
SPQ: 1
2RM600L-8/B
BrightKing
2,Lead
Quantity: 105800
In Stock
1000+ $0.0957
10000+ $0.0927
- +
x $0.0957
Ext. Price: $95.70
MOQ: 1000
Mult: 500
SPQ: 500
1812-090
FTR
90V 2kA 2end 1812GDT
Quantity: 2495
In Stock
24+
1+ $0.0458
10+ $0.0432
30+ $0.0422
100+ $0.0408
300+ $0.0399
2500+ $0.039
- +
x $0.0458
Ext. Price: $0.04
MOQ: 1
Mult: 1
SPQ: 2500
2027-07-BLF
BOURNS
2 10KA no 75V Plugins Through hole mounting 6mm(length)*8mm(height)
Quantity: 1400
Ship Date: 8-16 working days
1000+ $0.8335
3000+ $0.8261
- +
x $0.8335
Ext. Price: $833.50
MOQ: 1000
Mult: 100
SPQ: 100
GDT25-35-S1-RP
BOURNS
2 7KA SMD mount
Quantity: 930
Ship Date: 3-12 working days
1+ $0.7255
50+ $0.7255
100+ $0.6501
250+ $0.6501
500+ $0.6385
1500+ $0.6385
- +
x $0.7255
Ext. Price: $10.88
MOQ: 15
Mult: 1
BA301N-D
Bencent
Quantity: 5699
In Stock
23+
5+ $0.1658
50+ $0.1563
150+ $0.14
500+ $0.1013
2500+ $0.0975
7500+ $0.0947
- +
x $0.1658
Ext. Price: $0.82
MOQ: 5
Mult: 1
SPQ: 2500
2036-07-SMLF
BOURNS
3 10KA yes 75V SMD mount 7.3mm(length)*5mm(height)
Quantity: 2222
In Stock
24+
10+ $1.0507
250+ $0.9477
500+ $0.8741
1000+ $0.8406
- +
x $1.0507
Ext. Price: $10.50
MOQ: 10
Mult: 1
SPQ: 1000
2036-07-B3LF
BOURNS
3 10KA no 75V Plugins Through hole mounting 7.5mm(length)
Quantity: 12
Ship Date: 3-12 working days
1+ $2.45
5+ $2.1975
10+ $1.856
20+ $1.856
40+ $1.663
100+ $1.663
- +
x $2.45
Ext. Price: $12.25
MOQ: 5
Mult: 1
B88069X5110T502
TDK
2 5KA no 90V Through hole mounting,glue mount 6.05mm(length)
Quantity: 493
Ship Date: 3-12 working days
1+ $1.5968
10+ $1.3487
50+ $1.2084
100+ $1.2084
200+ $1.1868
500+ $1.1868
- +
x $1.5968
Ext. Price: $9.58
MOQ: 6
Mult: 1
2095-400-BLF
BOURNS
Bourns gas discharge tube, DC breakdown voltage4000V, axial, Maximum surge current 8kA
Quantity: 1334
Ship Date: 7-13 working days
500+ $0.8203
2500+ $0.8039
- +
x $0.8203
Ext. Price: $410.15
MOQ: 500
Mult: 500
K3RM090L-6
KUU
10KA
Quantity: 1000
Ship Date: 7-15 working days
100+ $0.2678
500+ $0.2633
1000+ $0.2566
- +
x $0.2678
Ext. Price: $26.78
MOQ: 100
Mult: 100
SPQ: 100
9071.99.0649
Huber+Suhner
2 yes 350V base mount,threaded mounting,Hinge mounting 16.2mm(length)
Quantity: 2
Ship Date: 3-12 working days
1+ $37.1331
5+ $37.1331
10+ $36.47
20+ $36.47
- +
x $37.1331
Ext. Price: $37.13
MOQ: 1
Mult: 1
2036-23-SM-RPLF-H
BOURNS
3 10KA no 230V SMD mount 7.3mm(length)*5mm(height)
Quantity: 935
Ship Date: 7-12 working days
1+ $2.912
- +
x $2.912
Ext. Price: $2.91
MOQ: 1
Mult: 1
SPQ: 1
2RL230L-5/B
BrightKing
2,Lead
Quantity: 5000
Ship Date: 3-8 working days
500+ $0.0771
- +
x $0.0771
Ext. Price: $38.54
MOQ: 500
Mult: 500
SPQ: 100
CG2350LTR
Littelfuse
2 20KA no 350V Plugins Through hole mounting 6.07mm(length)*8.1mm(height)
Quantity: 960
Ship Date: 6-12 working days
1+ $9.2696
- +
x $9.2696
Ext. Price: $27.80
MOQ: 3
Mult: 1
CG2350
Littelfuse
2 20KA no 350V welding mounting,SMD mount 6.07mm(length)
Quantity: 817
Ship Date: 6-13 working days
1+ $3.519
5+ $3.2085
10+ $2.97
50+ $1.518
1200+ $1.4385
- +
x $3.519
Ext. Price: $3.51
MOQ: 1
Mult: 1
SPQ: 1
CG5230MS
Littelfuse
2 5KA no 230V SMD mount 5mm(length)
Quantity: 437
Ship Date: 6-13 working days
1+ $3.312
5+ $2.7485
10+ $2.5415
50+ $1.9764
100+ $1.8252
250+ $1.6416
500+ $1.6308
900+ $1.491
- +
x $3.312
Ext. Price: $3.31
MOQ: 1
Mult: 1
SPQ: 1

Gas Discharge Tubes (GDT)

Gas Discharge Tubes (GDTs) are a type of overvoltage protection device that operates by using the ionization of gas to conduct electricity. They are designed to protect sensitive electronic equipment from voltage surges, which can be caused by lightning, power line switching, or other electrical disturbances.

Definition:
A Gas Discharge Tube is a passive electronic component that contains two or more electrodes within a gas-filled envelope. When the voltage across the GDT exceeds a certain threshold, the gas ionizes, creating a conductive path that allows the excess voltage to be safely discharged.

Function:
The primary function of a GDT is to clamp the voltage to a safe level by diverting the surge current away from the protected equipment. When the voltage across the GDT is below the ionization threshold, it acts as an open circuit, allowing normal operation of the equipment. Once the voltage exceeds the threshold, the GDT ionizes the gas, becoming a low-impedance path for the surge current to flow, thus protecting the equipment from damage.

Applications:
GDTs are widely used in various applications where overvoltage protection is necessary:
1. Telecommunications equipment, such as telephone exchanges and network infrastructure.
2. Power distribution systems to protect against lightning-induced surges.
3. Industrial control systems to safeguard against voltage spikes.
4. Consumer electronics, like televisions and computers, to protect against power surges.
5. Automotive electronics to protect against transient voltages.

Selection Criteria:
When selecting a GDT, several factors should be considered:
1. Voltage Rating: The GDT should have a continuous voltage rating that is compatible with the system's operating voltage.
2. Surge Current Capability: The GDT must be able to handle the expected surge current without failing.
3. Response Time: The GDT should have a fast response time to effectively protect against fast-rising surges.
4. Recovery Time: After discharging, the GDT should return to its non-conductive state quickly to minimize the impact on normal operation.
5. Physical Size and Mounting: The GDT should be compatible with the available space and mounting requirements of the equipment.
6. Environmental Considerations: The GDT should be suitable for the environmental conditions it will be exposed to, such as temperature and humidity.

In summary, Gas Discharge Tubes are crucial components in the protection of electronic systems from overvoltage events. They are selected based on their ability to handle the specific voltage and current requirements of the application, as well as their physical and environmental compatibility.
Please refer to the product rule book for details.