Home > Catalogue > Circuit Protection > Gas Discharge Tubes (GDT)

Gas Discharge Tubes (GDT)

Results:
Gas Discharge Tubes (GDT) Results:
Filter Results: -1/3528
Comprehensive
Price Priority
Stock Priority
Image
Part Number
Manufacturer
Description
Availability
Unit Price
Quantity
Operation
9071.99.0551 (73_Z-0-0-551)
Huber+Suhner
2 yes 600V base mount,threaded mounting,Hinge mounting 6mm(length)
Quantity: 24
Ship Date: 6-13 working days
1+ $28.061
5+ $25.4232
10+ $23.7168
50+ $21.8916
100+ $20.223
250+ $19.4565
- +
x $28.061
Ext. Price: $28.06
MOQ: 1
Mult: 1
SPQ: 1
X5-800XSMDT
SURGING
5KA SMD,5X4.2MM
Quantity: 3000
In Stock
24+
1+ $0.1331
10+ $0.1095
30+ $0.0909
100+ $0.0753
300+ $0.0735
1000+ $0.07
- +
x $0.1331
Ext. Price: $0.13
MOQ: 1
Mult: 1
SPQ: 1000
2036-20-B2LF
BOURNS
3 10KA no 200V Plugins Through hole mounting 7.5mm(length)*5.1mm(height)
Quantity: 1020
Ship Date: 7-9 working days
150+ $0.7668
350+ $0.7349
700+ $0.7175
1000+ $0.6868
- +
x $0.7668
Ext. Price: $115.02
MOQ: 150
Mult: 1
SPQ: 1
CG2230L
Littelfuse
2 20KA no 230V Through hole mounting 6.07mm(length)*8.1mm(height)
Quantity: 1470
Ship Date: 6-14 working days
150+ $1.5732
700+ $1.5504
- +
x $1.5732
Ext. Price: $235.98
MOQ: 150
Mult: 5
SPQ: 1
2027-15-SM-RP-LF
BOURNS
2 10KA no 150V SMD mount 6mm(length)*7.93mm(height)
Quantity: 3000
Ship Date: 6-14 working days
500+ $0.9882
1000+ $0.9243
1500+ $0.8892
2500+ $0.8664
5000+ $0.6042
12500+ $0.5814
- +
x $0.9882
Ext. Price: $494.10
MOQ: 500
Mult: 500
SPQ: 1
CG21000MS
Littelfuse
2 10KA no 1KV SMD mount 6.05mm(length)*8.3mm(height)
Quantity: 440
Ship Date: 6-13 working days
1+ $3.634
5+ $3.312
10+ $3.058
50+ $2.3652
100+ $2.2572
250+ $2.0196
500+ $1.6848
- +
x $3.634
Ext. Price: $3.63
MOQ: 1
Mult: 1
SPQ: 1
2057-12-BLF
BOURNS
Bourns gas discharge tube, DC breakdown voltage120V, axial, Maximum surge current 10kA
Quantity: 681
Ship Date: 3-12 working days
1+ $0.5625
10+ $0.4431
50+ $0.4261
100+ $0.4261
200+ $0.3818
500+ $0.3818
- +
x $0.5625
Ext. Price: $13.50
MOQ: 24
Mult: 1
2020-15T-C2LF
BOURNS
3 20KA no 60V Plugins Through hole mounting 13mm(length)*7.9mm(height)
Quantity: 227
Ship Date: 3-12 working days
1+ $4.4428
5+ $3.7524
10+ $3.7524
20+ $3.3621
40+ $3.3621
100+ $3.3621
- +
x $4.4428
Ext. Price: $13.32
MOQ: 3
Mult: 1
9071.99.0447
Huber+Suhner
Huber+Suhner gas discharge tube, DC breakdown voltage230V, panel mount
Quantity: 51
Ship Date: 10-15 working days
1+ $31.7054
10+ $31.2719
25+ $30.8839
50+ $30.4112
100+ $29.9394
- +
x $31.7054
Ext. Price: $63.41
MOQ: 2
Mult: 1
B88069X4890C103
TDK
2 10KA no 90V 6.05mm(length)
Quantity: 591
Ship Date: 3-12 working days
1+ $1.1704
50+ $1.1235
100+ $1.0486
250+ $1.0298
500+ $1.0298
1000+ $1.0298
- +
x $1.1704
Ext. Price: $9.36
MOQ: 8
Mult: 1
B88069X4300B152
TDK
2 20KA no 1.4KV Plugins base mount,threaded mounting,Hinge mounting 17.4mm(length)
Quantity: 18
Ship Date: 3-12 working days
1+ $21.0268
5+ $19.625
10+ $19.2746
25+ $19.2746
50+ $18.9242
150+ $18.9242
- +
x $21.0268
Ext. Price: $21.02
MOQ: 1
Mult: 1
B88069X9590B502
TDK
3 10KA no 150V Plugins Through hole mounting 13.4mm(length)
Quantity: 3051
Ship Date: 3-12 working days
1+ $2.5455
10+ $2.3497
50+ $2.3497
- +
x $2.5455
Ext. Price: $10.18
MOQ: 4
Mult: 1
B88069X2641T502
TDK
2 5KA no 680V~1KV Plugins Through hole mounting 6mm(length)
Quantity: 55
Ship Date: 3-12 working days
1+ $2.3
10+ $2.1231
50+ $1.9815
100+ $1.9461
200+ $1.9461
500+ $1.9461
- +
x $2.3
Ext. Price: $11.50
MOQ: 5
Mult: 1
2036-09-SM-RPLF
BOURNS
Bourns gas discharge tube, DC breakdown voltage90V, surface mount devices, Maximum surge current 20kA
Quantity: 5000
In Stock
24+
10+ $0.5779
300+ $0.5608
1000+ $0.5471
2000+ $0.538
- +
x $0.5779
Ext. Price: $5.77
MOQ: 10
Mult: 1
SPQ: 1000
SX51-75X
SURGING
5KA Plugins,D5.5XL6MM
Quantity: 35000
Ship Date: 5-8 working days
24+
500+ $0.0585
1000+ $0.057
2000+ $0.056
- +
x $0.0585
Ext. Price: $29.25
MOQ: 500
Mult: 500
SPQ: 500
SX51-350X
SURGING
2 5KA Plugins,D5.5XL6MM 5.5mm(length)*6mm(height)
Quantity: 40000
Ship Date: 5-8 working days
24+
500+ $0.0585
1000+ $0.057
2000+ $0.056
- +
x $0.0585
Ext. Price: $29.25
MOQ: 500
Mult: 500
SPQ: 500
B88069X3560T502
TDK
2 no Through hole mounting 6.05mm(length)
Quantity: 20
Ship Date: 7 working days
1+ $2.2193
100+ $1.7072
250+ $1.4346
500+ $1.2696
- +
x $2.2193
Ext. Price: $2.21
MOQ: 1
Mult: 1
SPQ: 1
BM302M
Bencent
Quantity: 1000
In Stock
23+
1000+ $0.3445
- +
x $0.3445
Ext. Price: $344.50
MOQ: 1000
Mult: 1000
SPQ: 1000
B88069X2190T502
TDK
2 2.5KA no 2.5KV Plugins Through hole mounting 7.9mm(length)
Quantity: 500
Ship Date: 7 working days
500+ $1.2512
- +
x $1.2512
Ext. Price: $625.60
MOQ: 500
Mult: 500
SPQ: 500
B88069X1470B502
TDK
3 10KA no 350V Plugins Through hole mounting 8.1mm(length)
Quantity: 426
Ship Date: 3-12 working days
1+ $2.6056
10+ $2.3346
50+ $2.3346
100+ $2.2929
200+ $2.2929
- +
x $2.6056
Ext. Price: $10.42
MOQ: 4
Mult: 1
B88069X2140T502
TDK
2 10KA no 800V Plugins Through hole mounting,glue mount 7.9mm(length)
Quantity: 271
Ship Date: 3-12 working days
1+ $3.4957
10+ $3.1321
50+ $3.1321
100+ $3.0762
200+ $3.0203
500+ $3.0203
- +
x $3.4957
Ext. Price: $10.48
MOQ: 3
Mult: 1
B88069X780S102
TDK
Quantity: 38
Ship Date: 7 working days
1+ $0.7172
100+ $0.5879
- +
x $0.7172
Ext. Price: $0.71
MOQ: 1
Mult: 1
SPQ: 1
2049-35-BT1LF
BOURNS
2 15KA no 350V Plugins Through hole mounting 6mm(length)*8mm(height)
Quantity: 217
Ship Date: 3-12 working days
1+ $0.5758
50+ $0.5758
100+ $0.5159
250+ $0.5159
500+ $0.5067
1000+ $0.5067
- +
x $0.5758
Ext. Price: $10.94
MOQ: 19
Mult: 1
B88069X8530B502
TDK
3 10KA no 420V~720V Plugins Through hole mounting 13.4mm(length)
Quantity: 504
Ship Date: 3-12 working days
1+ $2.3706
10+ $2.3706
- +
x $2.3706
Ext. Price: $9.48
MOQ: 4
Mult: 1
B88069X2380S102
TDK
EPCOS gas discharge tube, DC breakdown voltage350V, Through-hole, Maximum surge current 20kA
Quantity: 1600
Ship Date: 8-16 working days
200+ $1.0289
600+ $1.0199
- +
x $1.0289
Ext. Price: $205.78
MOQ: 200
Mult: 100
SPQ: 100

Gas Discharge Tubes (GDT)

Gas Discharge Tubes (GDTs) are a type of overvoltage protection device that operates by using the ionization of gas to conduct electricity. They are designed to protect sensitive electronic equipment from voltage surges, which can be caused by lightning, power line switching, or other electrical disturbances.

Definition:
A Gas Discharge Tube is a passive electronic component that contains two or more electrodes within a gas-filled envelope. When the voltage across the GDT exceeds a certain threshold, the gas ionizes, creating a conductive path that allows the excess voltage to be safely discharged.

Function:
The primary function of a GDT is to clamp the voltage to a safe level by diverting the surge current away from the protected equipment. When the voltage across the GDT is below the ionization threshold, it acts as an open circuit, allowing normal operation of the equipment. Once the voltage exceeds the threshold, the GDT ionizes the gas, becoming a low-impedance path for the surge current to flow, thus protecting the equipment from damage.

Applications:
GDTs are widely used in various applications where overvoltage protection is necessary:
1. Telecommunications equipment, such as telephone exchanges and network infrastructure.
2. Power distribution systems to protect against lightning-induced surges.
3. Industrial control systems to safeguard against voltage spikes.
4. Consumer electronics, like televisions and computers, to protect against power surges.
5. Automotive electronics to protect against transient voltages.

Selection Criteria:
When selecting a GDT, several factors should be considered:
1. Voltage Rating: The GDT should have a continuous voltage rating that is compatible with the system's operating voltage.
2. Surge Current Capability: The GDT must be able to handle the expected surge current without failing.
3. Response Time: The GDT should have a fast response time to effectively protect against fast-rising surges.
4. Recovery Time: After discharging, the GDT should return to its non-conductive state quickly to minimize the impact on normal operation.
5. Physical Size and Mounting: The GDT should be compatible with the available space and mounting requirements of the equipment.
6. Environmental Considerations: The GDT should be suitable for the environmental conditions it will be exposed to, such as temperature and humidity.

In summary, Gas Discharge Tubes are crucial components in the protection of electronic systems from overvoltage events. They are selected based on their ability to handle the specific voltage and current requirements of the application, as well as their physical and environmental compatibility.
Please refer to the product rule book for details.