Home > Catalogue > Circuit Protection > Gas Discharge Tubes (GDT)

Gas Discharge Tubes (GDT)

Results:
Gas Discharge Tubes (GDT) Results:
Filter Results: -1/3584
Comprehensive
Price Priority
Stock Priority
Image
Part Number
Manufacturer
Description
Availability
Unit Price
Quantity
Operation
UN2E8-3500LL
QY
8*6
Quantity: 2680
Ship Date: 3-5 working days
100+ $0.1346
1000+ $0.1256
3000+ $0.1212
- +
x $0.1346
Ext. Price: $13.46
MOQ: 100
Mult: 100
SPQ: 100
2R090SB-8
RUILON
10KA SMD,8X6MM SMD mount 6mm(length)*8mm(width)
Quantity: 50000
Ship Date: 2-4 weeks
24+
500+ $0.1267
1000+ $0.1246
2000+ $0.1214
3000+ $0.1193
13500+ $0.1109
- +
x $0.1267
Ext. Price: $63.35
MOQ: 500
Mult: 500
SPQ: 500
2R600TA-5
RUILON
2 5KA 600V Plugins,D5.5XL6MM Through hole mounting 5.5mm*6mm*6mm
Quantity: 100000
Ship Date: 2-4 weeks
24+
1000+ $0.1267
2000+ $0.1246
4000+ $0.1214
6000+ $0.1193
14000+ $0.1109
- +
x $0.1267
Ext. Price: $126.70
MOQ: 1000
Mult: 1000
SPQ: 1000
2R470TB-8
RUILON
10KA Plugins,D8XL6MM Through hole mounting 6mm(length)*8mm(width)
Quantity: 80000
Ship Date: 2-4 weeks
24+
800+ $0.1267
1600+ $0.1246
3200+ $0.1214
4800+ $0.1193
13600+ $0.1109
- +
x $0.1267
Ext. Price: $101.36
MOQ: 800
Mult: 800
SPQ: 800
SMD5050-1000
RUILON
Gas Discharge Tubes
Quantity: 100000
Ship Date: 2-4 weeks
24+
1000+ $0.1521
2000+ $0.1495
4000+ $0.1457
6000+ $0.1432
12000+ $0.1331
- +
x $0.1521
Ext. Price: $152.10
MOQ: 1000
Mult: 1000
SPQ: 1000
2035-20-BLF
BOURNS
2 5KA no 200V Plugins Through hole mounting 4.1mm(length)*5mm(height)
Quantity: 500
Ship Date: 5-12 working days
Within 3 years
100+ $1.1426
500+ $0.6761
1000+ $0.5471
2500+ $0.518
5000+ $0.5153
7500+ $0.5128
10000+ $0.5102
15000+ $0.5077
- +
x $1.1426
Ext. Price: $114.26
MOQ: 100
Mult: 100
B88069X3351T902
TDK
2 5KA no 600V SMD mount
Quantity: 656
Ship Date: 6-13 working days
1+ $2.0355
10+ $1.886
50+ $1.496
100+ $1.3176
250+ $1.2204
500+ $1.0248
900+ $0.8904
1800+ $0.8442
4500+ $0.8337
- +
x $2.0355
Ext. Price: $2.03
MOQ: 1
Mult: 1
SPQ: 1
B8G1500M
Bencent
10KA
Quantity: 2080
In Stock
24+
1+ $0.377
10+ $0.3023
- +
x $0.377
Ext. Price: $0.37
MOQ: 1
Mult: 1
SPQ: 700
2035-23-BT1LF
BOURNS
2 5KA no 230V Plugins Through hole mounting 4.2mm(length)*5mm(height)
Quantity: 1000
Ship Date: 5-12 working days
Within 3 years
1000+ $0.4549
3000+ $0.4276
5000+ $0.4212
8000+ $0.4148
10000+ $0.4086
- +
x $0.4549
Ext. Price: $454.90
MOQ: 1000
Mult: 1000
CG21000MS
Littelfuse
2 10KA no 1KV SMD mount 6.05mm(length)*8.3mm(height)
Quantity: 30
Ship Date: 6-13 working days
1+ $3.634
5+ $3.312
10+ $3.058
50+ $2.3436
100+ $1.998
250+ $1.827
500+ $1.638
- +
x $3.634
Ext. Price: $3.63
MOQ: 1
Mult: 1
SPQ: 1
9071.99.0551 (73_Z-0-0-551)
Huber+Suhner
2 yes 600V base mount,threaded mounting,Hinge mounting 6mm(length)
Quantity: 20
Ship Date: 6-13 working days
1+ $28.061
5+ $25.4232
10+ $23.7168
50+ $21.2835
100+ $20.223
250+ $19.4565
- +
x $28.061
Ext. Price: $28.06
MOQ: 1
Mult: 1
SPQ: 1
9071.99.0947
Huber+Suhner
2 yes 230V 19.4mm(length)
Quantity: 1
Ship Date: 6-13 working days
1+ $59.796
5+ $49.9932
10+ $47.1975
50+ $43.7745
100+ $42.441
- +
x $59.796
Ext. Price: $59.79
MOQ: 1
Mult: 1
SPQ: 1
3402.17.0044
Huber+Suhner
2 20KA wire mounting,free hanging,Through hole mounting
Quantity: 10
Ship Date: 6-13 working days
1+ $354.0564
10+ $311.6925
- +
x $354.0564
Ext. Price: $354.05
MOQ: 1
Mult: 1
SPQ: 1
2RE600L-8
FTR
10kA 2end PluginsGDT
Quantity: 100
Ship Date: 2-4 weeks
100+ $0.0931
300+ $0.0915
500+ $0.0891
15400+ $0.0835
- +
x $0.0931
Ext. Price: $9.31
MOQ: 100
Mult: 100
SPQ: 100
CG34.5L
Littelfuse
2 5KA no 4.5KV Through hole mounting 6mm(length)
Quantity: 338
Ship Date: 3-12 working days
1+ $2.5833
10+ $2.2256
100+ $2.1858
500+ $2.1858
- +
x $2.5833
Ext. Price: $10.33
MOQ: 4
Mult: 1
B88069X2380S102
TDK
EPCOS gas discharge tube, DC breakdown voltage350V, Through-hole, Maximum surge current 20kA
Quantity: 900
Ship Date: 8-16 working days
200+ $0.972
600+ $0.9635
- +
x $0.972
Ext. Price: $194.40
MOQ: 200
Mult: 100
SPQ: 100
B88069X2830S102
TDK
EPCOS gas discharge tube, DC breakdown voltage600V, Through-hole, Maximum surge current 12kA
Quantity: 122
Ship Date: 7 working days
100+ $0.8535
- +
x $0.8535
Ext. Price: $85.35
MOQ: 100
Mult: 100
SPQ: 100
B88069X780S102
TDK
Quantity: 38
Ship Date: 7 working days
1+ $0.7208
100+ $0.5908
- +
x $0.7208
Ext. Price: $0.72
MOQ: 1
Mult: 1
SPQ: 1
2R230TB-8
RUILON
10KA Plugins,D8XL6MM Through hole mounting 6mm(length)*8mm(width)
Quantity: 80000
Ship Date: 2-4 weeks
24+
800+ $0.1267
1600+ $0.1246
3200+ $0.1214
4800+ $0.1193
13600+ $0.1109
- +
x $0.1267
Ext. Price: $101.36
MOQ: 800
Mult: 800
SPQ: 800
100024242
Telegartner
1 15KA base mount
Quantity: 5
Ship Date: 7-15 working days
2+ $82.5865
5+ $77.577
10+ $72.1214
- +
x $82.5865
Ext. Price: $165.17
MOQ: 2
Mult: 1
SPQ: 1
B88069X4300B152
TDK
2 20KA no 1.4KV Plugins base mount,threaded mounting,Hinge mounting 17.4mm(length)
Quantity: 18
Ship Date: 3-12 working days
1+ $22.5707
5+ $21.066
10+ $20.6898
25+ $20.6898
50+ $20.3136
150+ $20.3136
- +
x $22.5707
Ext. Price: $22.57
MOQ: 1
Mult: 1
B88069X4890C103
TDK
2 10KA no 90V 6.05mm(length)
Quantity: 590
Ship Date: 3-12 working days
1+ $1.2155
50+ $1.1669
100+ $1.0891
250+ $1.0696
500+ $1.0696
1000+ $1.0696
- +
x $1.2155
Ext. Price: $9.72
MOQ: 8
Mult: 1
BTC351N
BORN
2KA 1812
Quantity: 200000
Ship Date: 3-10 working days
25+
2500+ $0.0718
7500+ $0.0705
12500+ $0.0688
- +
x $0.0718
Ext. Price: $179.50
MOQ: 2500
Mult: 2500
SPQ: 2500
2049-35-BT1LF
BOURNS
2 15KA no 350V Plugins Through hole mounting 6mm(length)*8mm(height)
Quantity: 217
Ship Date: 3-12 working days
1+ $0.6752
50+ $0.6752
100+ $0.605
250+ $0.605
500+ $0.5942
1000+ $0.5942
- +
x $0.6752
Ext. Price: $10.80
MOQ: 16
Mult: 1
SA2-3600-CLT-STD
BOURNS
2 5KA no 3.6KV Plugins Through hole mounting 8.9mm(length)*8.5mm(height)
Quantity: 2231
Ship Date: 6-13 working days
1+ $4.1745
5+ $3.4615
10+ $3.058
50+ $2.4948
100+ $2.3004
250+ $2.0055
500+ $1.848
1000+ $1.5855
2000+ $1.491
- +
x $4.1745
Ext. Price: $4.17
MOQ: 1
Mult: 1
SPQ: 1

Gas Discharge Tubes (GDT)

Gas Discharge Tubes (GDTs) are a type of overvoltage protection device that operates by using the ionization of gas to conduct electricity. They are designed to protect sensitive electronic equipment from voltage surges, which can be caused by lightning, power line switching, or other electrical disturbances.

Definition:
A Gas Discharge Tube is a passive electronic component that contains two or more electrodes within a gas-filled envelope. When the voltage across the GDT exceeds a certain threshold, the gas ionizes, creating a conductive path that allows the excess voltage to be safely discharged.

Function:
The primary function of a GDT is to clamp the voltage to a safe level by diverting the surge current away from the protected equipment. When the voltage across the GDT is below the ionization threshold, it acts as an open circuit, allowing normal operation of the equipment. Once the voltage exceeds the threshold, the GDT ionizes the gas, becoming a low-impedance path for the surge current to flow, thus protecting the equipment from damage.

Applications:
GDTs are widely used in various applications where overvoltage protection is necessary:
1. Telecommunications equipment, such as telephone exchanges and network infrastructure.
2. Power distribution systems to protect against lightning-induced surges.
3. Industrial control systems to safeguard against voltage spikes.
4. Consumer electronics, like televisions and computers, to protect against power surges.
5. Automotive electronics to protect against transient voltages.

Selection Criteria:
When selecting a GDT, several factors should be considered:
1. Voltage Rating: The GDT should have a continuous voltage rating that is compatible with the system's operating voltage.
2. Surge Current Capability: The GDT must be able to handle the expected surge current without failing.
3. Response Time: The GDT should have a fast response time to effectively protect against fast-rising surges.
4. Recovery Time: After discharging, the GDT should return to its non-conductive state quickly to minimize the impact on normal operation.
5. Physical Size and Mounting: The GDT should be compatible with the available space and mounting requirements of the equipment.
6. Environmental Considerations: The GDT should be suitable for the environmental conditions it will be exposed to, such as temperature and humidity.

In summary, Gas Discharge Tubes are crucial components in the protection of electronic systems from overvoltage events. They are selected based on their ability to handle the specific voltage and current requirements of the application, as well as their physical and environmental compatibility.
Please refer to the product rule book for details.