Home > Catalogue > Circuit Protection > Gas Discharge Tubes (GDT)

Gas Discharge Tubes (GDT)

Results:
Gas Discharge Tubes (GDT) Results:
Filter Results: -1/3303
Comprehensive
Price Priority
Stock Priority
Image
Part Number
Manufacturer
Description
Availability
Unit Price
Quantity
Operation
2056-23-B2LF
BOURNS
3 5KA no 230V Plugins Through hole mounting 8.5mm(length)
Quantity: 1000
Ship Date: 7-9 working days
200+ $0.5432
500+ $0.5175
1000+ $0.4818
- +
x $0.5432
Ext. Price: $108.64
MOQ: 200
Mult: 1
SPQ: 1
2RM600L-8
BrightKing
2,Lead
Quantity: 6439
In Stock
2515+
5+ $0.1934
50+ $0.155
200+ $0.1388
500+ $0.1178
2500+ $0.1079
5000+ $0.1017
- +
x $0.1934
Ext. Price: $0.96
MOQ: 5
Mult: 5
SPQ: 100
2RL1600L-8/B
BrightKing
5KA Plugins
Quantity: 4000
In Stock
1000+ $0.1338
10000+ $0.1298
- +
x $0.1338
Ext. Price: $133.80
MOQ: 1000
Mult: 500
SPQ: 500
2RP350L-8/B
YAGEO
2 20KA Through hole mounting
Quantity: 234
Ship Date: 6-12 working days
20+ $0.9247
40+ $0.7938
100+ $0.7292
- +
x $0.9247
Ext. Price: $24.04
MOQ: 26
Mult: 1
2027-09-BLF
BOURNS
2 10KA no 90V Plugins Through hole mounting 6mm(length)*8mm(height)
Quantity: 350
Ship Date: 7-10 working days
200+ $0.5325
- +
x $0.5325
Ext. Price: $106.50
MOQ: 200
Mult: 1
SPQ: 1
CG34.0LTR
Littelfuse
2 5KA no 4KV Through hole mounting 6mm(length)
Quantity: 1500
Ship Date: 2-4 weeks
1500+ $1.0994
3000+ $1.0811
6000+ $1.0627
12000+ $1.0444
- +
x $1.0994
Ext. Price: $1649.10
MOQ: 1500
Mult: 500
SPQ: 500
GDT28H-300-BRP
BOURNS
2 5KA Through hole mounting 6mm(length)
Quantity: 313
Ship Date: 3-12 working days
1+ $1.3954
50+ $1.3396
100+ $1.2503
250+ $1.2279
500+ $1.2279
1000+ $1.2279
- +
x $1.3954
Ext. Price: $11.16
MOQ: 8
Mult: 1
GDT35-35-S1-BK
BOURNS
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors Next-Generation GDT 5mm 350V
Quantity: 1000
Ship Date: 6-14 working days
1000+ $0.8137
- +
x $0.8137
Ext. Price: $813.70
MOQ: 1000
Mult: 1000
SPQ: 1
BJ091M-1
Bencent
Quantity: 2000
Ship Date: 3-7 working days
23+
1000+ $0.1947
- +
x $0.1947
Ext. Price: $194.70
MOQ: 1000
Mult: 1000
SPQ: 1000
BM351M-1
Bencent
Quantity: 80000
In Stock
23+
500+ $0.5207
- +
x $0.5207
Ext. Price: $260.35
MOQ: 500
Mult: 500
SPQ: 500
P2300SA
SALLTECH
encapsulation:SMB/DO-214AA
Quantity: 100000
Ship Date: 5-7 working days
3000+ $0.0308
9000+ $0.0296
15000+ $0.0278
57000+ $0.0271
- +
x $0.0308
Ext. Price: $92.40
MOQ: 3000
Mult: 3000
SPQ: 3000
3RM075L-8/B
BrightKing
10KA
Quantity: 450
In Stock
25+
1+ $0.3485
50+ $0.2665
500+ $0.2485
10000+ $0.2458
15000+ $0.2443
- +
x $0.3485
Ext. Price: $3.48
MOQ: 10
Mult: 1
SPQ: 500
FA55-302-A22F-M
MITSUBISHI ELECTRIC
2 2.5KA Through hole mounting
Quantity: 500
Ship Date: 7-12 working days
500+ $0.9422
1000+ $0.8682
1500+ $0.8275
2500+ $0.7787
3500+ $0.748
5000+ $0.7166
12500+ $0.7137
- +
x $0.9422
Ext. Price: $471.10
MOQ: 500
Mult: 500
SPQ: 1
2RL800M-6
YAGEO
Gas Discharge Tubs
Quantity: 620
Ship Date: 7-12 working days
1+ $1.027
5+ $0.8528
10+ $0.6545
50+ $0.5428
100+ $0.4824
250+ $0.4336
- +
x $1.027
Ext. Price: $2.05
MOQ: 2
Mult: 1
SPQ: 1
2057-13-BLF
BOURNS
2 5KA no 130V Plugins Through hole mounting 6mm(length)
Quantity: 310
Ship Date: 10-15 working days
1+ $0.6557
50+ $0.606
100+ $0.5437
200+ $0.5434
- +
x $0.6557
Ext. Price: $84.58
MOQ: 129
Mult: 1
B88069X4301S102
TDK
2 5KA no 1.5KV Plugins,D8XL6MM Through hole mounting 6mm(length)
Quantity: 350
In Stock
2524+
1+ $0.4984
10+ $0.4237
30+ $0.3746
100+ $0.3307
500+ $0.3
- +
x $0.4984
Ext. Price: $0.49
MOQ: 1
Mult: 1
SPQ: 100
B88069X6071T253
TDK
EPCOS gas discharge tube, DC breakdown voltage150V, surface mount devices, Maximum surge current 2kA
Quantity: 7500
Ship Date: 8-16 working days
2500+ $0.4078
7500+ $0.4042
- +
x $0.4078
Ext. Price: $1019.50
MOQ: 2500
Mult: 2500
SPQ: 2500
B3Q090
Bencent
3 6KA SMD SMD mount 6.8mm*3.5mm*3.5mm
Quantity: 3162
In Stock
23+
5+ $0.442
50+ $0.4168
150+ $0.3734
500+ $0.2703
2000+ $0.2602
6000+ $0.2526
- +
x $0.442
Ext. Price: $2.21
MOQ: 5
Mult: 1
SPQ: 2000
2RK3600L-8/B
BrightKing
3KA Plugins
Quantity: 1500
In Stock
1000+ $0.1252
10000+ $0.1215
- +
x $0.1252
Ext. Price: $125.20
MOQ: 1000
Mult: 500
SPQ: 500
GTCC23-231M-R01-2
Littelfuse
2 1KA no 230V 1812 SMD mount 4.5mm*3.2mm*3.2mm
Quantity: 4000
Ship Date: 10-15 working days
25+
2000+ $0.9518
- +
x $0.9518
Ext. Price: $1903.60
MOQ: 2000
Mult: 2000
SPQ: 2000
2051-09-SM-RPLF
BOURNS
Bourns gas discharge tube, DC breakdown voltage90V, surface mount devices, Maximum surge current 2kA
Quantity: 59
In Stock
2504+
1+ $0.3881
10+ $0.3081
30+ $0.2761
- +
x $0.3881
Ext. Price: $0.38
MOQ: 1
Mult: 1
SPQ: 2500
B88069X0780S102
TDK
EPCOS gas discharge tube, DC breakdown voltage540 → 720V, Through-hole, Maximum surge current 10kA
Quantity: 121
Ship Date: 5-10 working days
121+ $0.4463
- +
x $0.4463
Ext. Price: $54.00
MOQ: 121
Mult: 121
SPQ: 121
BS1300N-C-F
Bencent
Quantity: 90000
In Stock
23+
3000+ $0.1564
- +
x $0.1564
Ext. Price: $469.20
MOQ: 3000
Mult: 3000
SPQ: 3000
P0640SC
YFW
Quantity: 90000
Ship Date: 7-14 working days
3000+ $0.0513
6000+ $0.0504
9000+ $0.0492
- +
x $0.0513
Ext. Price: $153.90
MOQ: 3000
Mult: 3000
SPQ: 3000
CG75MSTR
Littelfuse
2 20KA no 75V SMD welding mounting,SMD mount 6.07mm(length)*8.3mm(height)
Quantity: 970
Ship Date: 6-12 working days
1+ $9.2696
- +
x $9.2696
Ext. Price: $27.80
MOQ: 3
Mult: 1

Gas Discharge Tubes (GDT)

Gas Discharge Tubes (GDTs) are a type of overvoltage protection device that operates by using the ionization of gas to conduct electricity. They are designed to protect sensitive electronic equipment from voltage surges, which can be caused by lightning, power line switching, or other electrical disturbances.

Definition:
A Gas Discharge Tube is a passive electronic component that contains two or more electrodes within a gas-filled envelope. When the voltage across the GDT exceeds a certain threshold, the gas ionizes, creating a conductive path that allows the excess voltage to be safely discharged.

Function:
The primary function of a GDT is to clamp the voltage to a safe level by diverting the surge current away from the protected equipment. When the voltage across the GDT is below the ionization threshold, it acts as an open circuit, allowing normal operation of the equipment. Once the voltage exceeds the threshold, the GDT ionizes the gas, becoming a low-impedance path for the surge current to flow, thus protecting the equipment from damage.

Applications:
GDTs are widely used in various applications where overvoltage protection is necessary:
1. Telecommunications equipment, such as telephone exchanges and network infrastructure.
2. Power distribution systems to protect against lightning-induced surges.
3. Industrial control systems to safeguard against voltage spikes.
4. Consumer electronics, like televisions and computers, to protect against power surges.
5. Automotive electronics to protect against transient voltages.

Selection Criteria:
When selecting a GDT, several factors should be considered:
1. Voltage Rating: The GDT should have a continuous voltage rating that is compatible with the system's operating voltage.
2. Surge Current Capability: The GDT must be able to handle the expected surge current without failing.
3. Response Time: The GDT should have a fast response time to effectively protect against fast-rising surges.
4. Recovery Time: After discharging, the GDT should return to its non-conductive state quickly to minimize the impact on normal operation.
5. Physical Size and Mounting: The GDT should be compatible with the available space and mounting requirements of the equipment.
6. Environmental Considerations: The GDT should be suitable for the environmental conditions it will be exposed to, such as temperature and humidity.

In summary, Gas Discharge Tubes are crucial components in the protection of electronic systems from overvoltage events. They are selected based on their ability to handle the specific voltage and current requirements of the application, as well as their physical and environmental compatibility.
Please refer to the product rule book for details.