855-401/400-501
WAGO
Wago Current Transformers, 855series, 400A, 1 Aoutput, DIN
Quantity: 13
Ship Date: 3-12 working days
1+ $63.99
- +
x $63.99
Ext. Price: $63.99
MOQ: 1
Mult: 1
CTA6X500A5A
Carlo Gavazzi
Current Transformers, CTAseries, turns_ratio 500:5, Separate core type
Quantity: 17
Ship Date: 7-13 working days
1+ $180.148
- +
x $180.148
Ext. Price: $180.14
MOQ: 1
Mult: 1
ECSTA1V0504-1060-R
EATON
60:1 7A 295μH 50KHz~1MHz SMD mount 4.8mm*3.65mm*3.55mm
Quantity: 1999
Ship Date: 6-13 working days
1+ $7.958
10+ $7.073
250+ $6.531
500+ $6.3735
1000+ $6.2895
2000+ $4.116
- +
x $7.958
Ext. Price: $7.95
MOQ: 1
Mult: 1
SPQ: 1
1033483
PHOENIX CONTACT
Phoenix Current Transformers, PACT RCPseries, 1 Aoutput, Rogowski coil type
Quantity: 1
Ship Date: 5-10 working days
1+ $358.6878
- +
x $358.6878
Ext. Price: $358.68
MOQ: 1
Mult: 1
B82801B0984A070
TDK
1:70 20A 980μH 50KHz~1MHz SMD SMD mount 7.11mm*8.13mm*5.08mm
Quantity: 1273
Ship Date: 6-13 working days
1+ $2.369
10+ $2.1965
25+ $1.991
100+ $1.9224
250+ $1.8792
500+ $1.6092
900+ $1.5435
1800+ $1.449
4500+ $1.428
- +
x $2.369
Ext. Price: $2.36
MOQ: 1
Mult: 1
SPQ: 1
4NC5112-2CB21
SIEMENS
current transformer 50/5 A, 1.2 VA CL 1.0
Quantity: 4
Ship Date: 5-10 working days
1+ $80.5152
- +
x $80.5152
Ext. Price: $80.51
MOQ: 1
Mult: 1
2276117
PHOENIX CONTACT
1:30 150A 50Hz~60Hz DINRail installation 85mm*30mm*108mm
Quantity: 100
Ship Date: 10-20 weeks
1+ $45.0977
10+ $44.6986
- +
x $45.0977
Ext. Price: $45.09
MOQ: 1
Mult: 1
SPQ: 1
PA1005.070QNL
Pulse Electronics
1:70 20A 980μH 50KHz~1MHz SMD SMD mount 7.21mm*8.38mm*5.5mm
Quantity: 560
Ship Date: 7-12 working days
1+ $2.808
10+ $1.8695
25+ $1.5189
40+ $1.4251
120+ $1.3874
240+ $1.35
480+ $1.3387
960+ $1.185
4920+ $1.0875
- +
x $2.808
Ext. Price: $2.80
MOQ: 1
Mult: 1
SPQ: 1
1382387
PHOENIX CONTACT
100:1 100A 50Hz~60Hz wire mounting,free hanging,Through hole mounting 73mm*22mm*35mm
Quantity: 4
Ship Date: 7-13 working days
1+ $106.6259
- +
x $106.6259
Ext. Price: $106.62
MOQ: 1
Mult: 1
XS03-395115S 000000
Sifam Tinsley
Sifam Tinsley Current Transformers, Omega10series, turns_ratio 1000:5, Clamp mounting type
Quantity: 27
Ship Date: 7-13 working days
1+ $89.3359
- +
x $89.3359
Ext. Price: $89.33
MOQ: 1
Mult: 1
AT 150 B10
LEM
LEM Current Transformers, ATseries, 150A, turns_ratio 150:1
Quantity: 9
Ship Date: 7-13 working days
1+ $81.0191
5+ $72.9176
10+ $71.4588
- +
x $81.0191
Ext. Price: $81.01
MOQ: 1
Mult: 1
DVL 1500
LEM
LEM Current Transformers, DVLseries, 50 mAoutput
Quantity: 12
Ship Date: 7-13 working days
1+ $504.4105
- +
x $504.4105
Ext. Price: $504.41
MOQ: 1
Mult: 1
R5487L401KP-TR
RICOH
Quantity: 1252759
Ship Date: 9-13 working days
15+
500+ $0.1762
1000+ $0.1746
5000+ $0.1729
- +
x $0.1762
Ext. Price: $120.16
MOQ: 682
Mult: 1
SPQ: 1
CR2SFT-800
CR MAGNETICS
80A 50Hz~400Hz 80:5 base mount 68.1mm*44.5mm*68.1mm
Quantity: 9
Ship Date: 7-12 working days
1+ $21.5696
10+ $19.4251
25+ $18.6239
50+ $18.0371
100+ $17.4667
250+ $16.7374
500+ $16.2041
- +
x $21.5696
Ext. Price: $21.56
MOQ: 1
Mult: 1
SPQ: 1
2276120
PHOENIX CONTACT
1:40 200A 50Hz~60Hz DINRail installation 85mm*30mm*108mm
Quantity: 2
Ship Date: 7-12 working days
1+ $59.778
- +
x $59.778
Ext. Price: $59.77
MOQ: 1
Mult: 1
SPQ: 1
CR2RL-301
CR MAGNETICS
300A 50Hz~400Hz 300:5 26.7mm(height)
Quantity: 1
Ship Date: 7-12 working days
1+ $21.5696
10+ $19.4251
25+ $18.6239
50+ $18.0371
100+ $17.4667
250+ $16.7374
500+ $16.2041
- +
x $21.5696
Ext. Price: $21.56
MOQ: 1
Mult: 1
SPQ: 1
ART-B22-D125
LEM
258μH 50Hz,60Hz 81Ω wire mounting,free hanging 56.01mm*33.69mm*18.91mm
Quantity: 77
Ship Date: 7-12 working days
1+ $79.7264
5+ $73.8442
10+ $71.6529
30+ $68.5433
60+ $66.7885
120+ $65.1775
- +
x $79.7264
Ext. Price: $79.72
MOQ: 1
Mult: 1
SPQ: 1
XS02-275015S 000000
Sifam Tinsley
Sifam Tinsley Current Transformers, Omega10series, turns_ratio 250:5, Clamp mounting type
Quantity: 19
Ship Date: 7-13 working days
1+ $57.4239
- +
x $57.4239
Ext. Price: $57.42
MOQ: 1
Mult: 1
CT-0400-F20
Littelfuse
400A 400:5
Quantity: 1
Ship Date: 7-12 working days
1+ $106.3504
10+ $95.5458
25+ $91.5329
50+ $88.6018
100+ $85.759
- +
x $106.3504
Ext. Price: $106.35
MOQ: 1
Mult: 1
SPQ: 1
CR5RL-122
CR MAGNETICS
1.2KA 50Hz~400Hz 1200:5 wire mounting,free hanging,Through hole mounting 90.4mm(length)*27.9mm(height)
Quantity: 3
Ship Date: 7-12 working days
1+ $34.6572
- +
x $34.6572
Ext. Price: $34.65
MOQ: 1
Mult: 1
SPQ: 1
S27S300D15YM
TAMURA
300A DC~100KHz panel mount 68mm(length)*56.5mm(height)
Quantity: 3
Ship Date: 5-12 working days
Within 2 years
1+ $49.5305
5+ $43.524
10+ $42.228
25+ $39.396
75+ $37.4115
150+ $35.742
300+ $34.503
- +
x $49.5305
Ext. Price: $49.53
MOQ: 1
Mult: 1
AS-404
Amgis Toroids
CURR SENSE XFMR 50A 1:100 VRT
Quantity: 100
Ship Date: 7-12 working days
1+ $4.5576
10+ $4.1137
25+ $3.8022
50+ $3.6849
100+ $3.5706
300+ $3.3958
500+ $3.317
1000+ $3.2126
- +
x $4.5576
Ext. Price: $4.55
MOQ: 1
Mult: 1
SPQ: 1
855-505/1000-1001
WAGO
50Hz~60Hz
Quantity: 200000
Ship Date: 4-12 weeks
20+
1+ $107.2923
5+ $101.1028
10+ $97.0596
- +
x $107.2923
Ext. Price: $107.29
MOQ: 1
Mult: 1
SPQ: 1
855-4005/150-101
WAGO
150:5 150A 50Hz~60Hz 150:5 wire mounting,base mount 57.2mm*49mm*67mm
Quantity: 200000
Ship Date: 4-12 weeks
20+
1+ $283.4836
5+ $267.1274
10+ $256.4423
- +
x $283.4836
Ext. Price: $283.48
MOQ: 1
Mult: 1
SPQ: 1
DK 200 B420
LEM
200:1 200A 200:1 panel mount 89.7mm(width)*68.6mm(height)
Quantity: 7
Ship Date: 7-13 working days
1+ $524.1027
6+ $513.6205
- +
x $524.1027
Ext. Price: $524.10
MOQ: 1
Mult: 1

Current Transformers (CT)

Current Transformers (CTs) are devices used in electrical power systems to convert high alternating current (AC) to a lower, safer level for measurement and protection purposes. They are essential components in power distribution and control systems.

Definition:
A current transformer is an instrument transformer designed to provide a current that is proportional to the current in a primary circuit. It typically consists of a toroidal core with a primary winding and a secondary winding. The primary winding is connected in series with the load, while the secondary winding is connected to the measuring or protective devices.

Function:
1. Measurement: CTs allow for the accurate measurement of current in high-voltage circuits without the need for high-voltage-rated meters or protection relays.
2. Protection: They are used in conjunction with relays to provide overcurrent, short-circuit, and earth-fault protection in power systems.
3. Control: CTs enable the control of power flow in circuits by providing feedback to control systems.

Applications:
1. Power Distribution: In substations and distribution boards to monitor and control the flow of electricity.
2. Metering: For billing purposes in utility companies to measure the amount of electricity consumed by customers.
3. Protection Systems: To detect faults and initiate circuit breakers to prevent damage to the electrical infrastructure.

Selection Criteria:
1. Rated Current: The CT should be rated for the maximum current expected in the primary circuit.
2. Accuracy Class: Depending on the application, CTs are classified by their accuracy (e.g., 0.5, 0.2, 0.1 class).
3. Turns Ratio: The ratio of primary to secondary turns determines the current transformation ratio.
4. Insulation Level: Must be suitable for the voltage level of the primary circuit.
5. Environmental Conditions: CTs must be rated for the environmental conditions they will be exposed to, such as temperature, humidity, and pollution levels.
6. Size and Physical Characteristics: The physical size and shape of the CT must be compatible with the installation location and the equipment it is connected to.

In summary, current transformers are vital for the safe and efficient operation of electrical systems, providing a means to measure, control, and protect against electrical faults in high-current applications. Their selection should be based on the specific requirements of the system they will be used in.
Please refer to the product rule book for details.