Home > Catalogue > Magnetic Components > Current Transformers (CT)

Current Transformers (CT)

Results:
Current Transformers (CT) Results:
Filter Results: -1/1950
Comprehensive
Price Priority
Stock Priority
Image
Part Number
Manufacturer
Description
Availability
Unit Price
Quantity
Operation
855-505/800-1001
WAGO
800:5 800A 50Hz~60Hz 800:5 base mount 85mm*35mm*105.25mm
Quantity: 44
Ship Date: 4-7 working days
1+ $104.6253
10+ $103.7234
100+ $101.9195
- +
x $104.6253
Ext. Price: $104.62
MOQ: 1
Mult: 1
PE-64487NL
Pulse Electronics
20A 20mH 20KHz~200KHz 100:1 Plugins Through hole mounting 22.86mm*17.78mm*17.78mm
Quantity: 500
Ship Date: 7-12 working days
1+ $6.3936
10+ $5.5609
25+ $5.336
50+ $5.1711
100+ $5.0105
250+ $4.8047
500+ $4.6539
1000+ $4.5072
- +
x $6.3936
Ext. Price: $6.39
MOQ: 1
Mult: 1
SPQ: 1
CT164M300/5-2.5/1-001
HOBUT
HOBUT Current Transformers, CT164series, 300A, 5 Aoutput, turns_ratio 300:5, DIN
Quantity: 28
Ship Date: 7-13 working days
1+ $31.9119
- +
x $31.9119
Ext. Price: $31.91
MOQ: 1
Mult: 1
90.N9.09.000.0
LEM
LEM Current Transformers, LESseries, 6A, turns_ratio 6:1
Quantity: 59
Ship Date: 7-13 working days
1+ $18.0415
- +
x $18.0415
Ext. Price: $36.08
MOQ: 2
Mult: 1
CT143M400/5-5/0.5-001
HOBUT
HOBUT Current Transformers, CT143series, 400A, 5 Aoutput, turns_ratio 400:5, DIN
Quantity: 1
Ship Date: 7-13 working days
1+ $28.9665
- +
x $28.9665
Ext. Price: $28.96
MOQ: 1
Mult: 1
855-305/200-501
WAGO
200:5 50Hz~60Hz 200:5
Quantity: 117
Ship Date: 4-7 working days
1+ $72.3672
3+ $71.7434
12+ $70.4957
- +
x $72.3672
Ext. Price: $72.36
MOQ: 1
Mult: 1
ASM-010
Amgis Toroids
50Hz,60Hz Plugins Through hole mounting 17.2mm*9.53mm*20.4mm
Quantity: 270
Ship Date: 7-12 working days
1+ $4.59
10+ $4.1515
25+ $3.8376
40+ $3.7575
80+ $3.6417
230+ $3.471
500+ $3.3498
1000+ $3.2447
- +
x $4.59
Ext. Price: $4.59
MOQ: 1
Mult: 1
SPQ: 1
XS01-245051S 000000
Sifam Tinsley
Sifam Tinsley Current Transformers, Omega10series, turns_ratio 200:5, Clamp mounting type
Quantity: 3
Ship Date: 7-13 working days
1+ $58.1363
- +
x $58.1363
Ext. Price: $58.13
MOQ: 1
Mult: 1
CSE184L
Triad Magnetics
1:16.67 1A 50Hz~400Hz DIP Through hole mounting 21.5mm*24mm*18mm
Quantity: 16
Ship Date: 3-12 working days
1+ $2.8977
10+ $2.8977
25+ $2.5964
50+ $2.5964
100+ $2.55
500+ $2.55
- +
x $2.8977
Ext. Price: $11.59
MOQ: 4
Mult: 1
CST-1020
Triad Magnetics
20A 50Hz,60Hz 40Ω 1000:1 Plugins Through hole mounting 23.5mm*12mm*24.8mm
Quantity: 222
Ship Date: 9-11 working days
23+
15+ $4.862
40+ $4.796
100+ $4.73
250+ $4.598
- +
x $4.862
Ext. Price: $97.24
MOQ: 20
Mult: 1
SPQ: 120
CST206-1A-B
Triad Magnetics
110A 14mH 20KHz~200KHz 2KVμs 580mΩ 100:1 Plugins Through hole mounting 27.31mm*10.16mm*31.12mm
Quantity: 10
Ship Date: 7-12 working days
1+ $7.1496
10+ $6.2119
25+ $5.9609
50+ $5.7764
100+ $5.5966
250+ $5.3663
500+ $5.1976
1000+ $5.0336
- +
x $7.1496
Ext. Price: $7.14
MOQ: 1
Mult: 1
SPQ: 1
AS-407
talema
1:500 80A 20KHz~200KHz 7.5KVμs Through hole mounting 17.2mm*9.53mm*20.4mm
Quantity: 2501
Ship Date: 6-12 working days
1+ $7.2225
5+ $6.9065
25+ $5.8747
125+ $5.5265
- +
x $7.2225
Ext. Price: $621.13
MOQ: 86
Mult: 1
SPQ: 1
101990064
Seeed Studio
60A wire mounting,base mount 13mm(length)*13mm(width)
Quantity: 23
Ship Date: 6-13 working days
1+ $7.935
- +
x $7.935
Ext. Price: $7.93
MOQ: 1
Mult: 1
SPQ: 1
2910326
PHOENIX CONTACT
Phoenix Current Transformers, PACT RCPseries, 4000A, 1 Aoutput, Rogowski coil type, Used for modification
Quantity: 1
Ship Date: 7-12 working days
1+ $480.3344
- +
x $480.3344
Ext. Price: $480.33
MOQ: 1
Mult: 1
SPQ: 1
2277103
PHOENIX CONTACT
1:120 600A 50Hz~60Hz DINRail installation 60mm*30mm*80mm
Quantity: 100
Ship Date: 10-20 weeks
1+ $22.3312
10+ $22.1336
- +
x $22.3312
Ext. Price: $44.66
MOQ: 2
Mult: 1
SPQ: 1
2277093
PHOENIX CONTACT
Phoenix,PACTMCR-V2-3015-60-400-5A-1,Current Transformers,400A 50Hz~60Hz DINRail installation 60mm*30mm*80mm
Quantity: 132
Ship Date: 7-14 working days
1+ $23.3193
- +
x $23.3193
Ext. Price: $46.63
MOQ: 2
Mult: 1
SPQ: 1
CTV3X200A333MV
Carlo Gavazzi
Current Transformers, CTVseries, Separate core type
Quantity: 1
Ship Date: 5-10 working days
1+ $57.8463
- +
x $57.8463
Ext. Price: $57.84
MOQ: 1
Mult: 1
TCD12BS32AE
Carlo Gavazzi
21A DINRail installation 58mm*221mm*49mm
Quantity: 3
Ship Date: 7-12 working days
1+ $741.988
5+ $704.8912
10+ $682.6321
- +
x $741.988
Ext. Price: $741.98
MOQ: 1
Mult: 1
SPQ: 1
METSECT5GD040
Schneider Electric
400/5A 400/5A
Quantity: 2
Ship Date: 5-10 working days
1+ $1675.5837
- +
x $1675.5837
Ext. Price: $1675.58
MOQ: 1
Mult: 1
HO 50-S/SP30-0100
LEM
125:1 -125A~125A 125:1 panel mount 45mm(width)*40.8mm(height)
Quantity: 10
Ship Date: 7-13 working days
1+ $24.5083
5+ $18.55
10+ $17.5058
- +
x $24.5083
Ext. Price: $49.01
MOQ: 2
Mult: 1
FIS115NL
Pulse Electronics
1:100 25A 18mH 500KHz(Max) 350Vμs 2Ω Through hole mounting 17.6mm*15mm*12.5mm
Quantity: 12717
Ship Date: 10-15 working days
25+
300+ $1.0584
600+ $1.021
1200+ $0.9461
- +
x $1.0584
Ext. Price: $476.28
MOQ: 450
Mult: 30
SPQ: 30
XM22-415151S000000
Sifam Tinsley
Sifam Tinsley Current Transformers, Omegaseries, 1250A, 5 Aoutput, turns_ratio 1250:5
Quantity: 1
Ship Date: 7-13 working days
1+ $36.8304
- +
x $36.8304
Ext. Price: $36.83
MOQ: 1
Mult: 1
HO 10-P/SP33-1000
LEM
25:1 -25A~25A 25:1 panel mount 23.94mm(width)*20.9mm(height)
Quantity: 2
Ship Date: 7-13 working days
1+ $13.557
5+ $13.0789
10+ $9.6761
- +
x $13.557
Ext. Price: $27.11
MOQ: 2
Mult: 1
7492540050
WURTH
1MHz
Quantity: 900
Ship Date: 7-12 working days
225+ $2.5609
450+ $2.4811
675+ $2.4354
1125+ $2.3789
1575+ $2.3422
2250+ $2.304
- +
x $2.5609
Ext. Price: $576.20
MOQ: 225
Mult: 225
SPQ: 1
CSNS300F
Honeywell
600:1 300A 600:1 base mount 67.5mm*17.9mm*61.2mm
Quantity: 10
Ship Date: 7-9 working days
1+ $159.4092
2+ $152.0519
4+ $147.7333
7+ $144.894
- +
x $159.4092
Ext. Price: $159.40
MOQ: 1
Mult: 1
SPQ: 1

Current Transformers (CT)

Current Transformers (CTs) are devices used in electrical power systems to convert high alternating current (AC) to a lower, safer level for measurement and protection purposes. They are essential components in power distribution and control systems.

Definition:
A current transformer is an instrument transformer designed to provide a current that is proportional to the current in a primary circuit. It typically consists of a toroidal core with a primary winding and a secondary winding. The primary winding is connected in series with the load, while the secondary winding is connected to the measuring or protective devices.

Function:
1. Measurement: CTs allow for the accurate measurement of current in high-voltage circuits without the need for high-voltage-rated meters or protection relays.
2. Protection: They are used in conjunction with relays to provide overcurrent, short-circuit, and earth-fault protection in power systems.
3. Control: CTs enable the control of power flow in circuits by providing feedback to control systems.

Applications:
1. Power Distribution: In substations and distribution boards to monitor and control the flow of electricity.
2. Metering: For billing purposes in utility companies to measure the amount of electricity consumed by customers.
3. Protection Systems: To detect faults and initiate circuit breakers to prevent damage to the electrical infrastructure.

Selection Criteria:
1. Rated Current: The CT should be rated for the maximum current expected in the primary circuit.
2. Accuracy Class: Depending on the application, CTs are classified by their accuracy (e.g., 0.5, 0.2, 0.1 class).
3. Turns Ratio: The ratio of primary to secondary turns determines the current transformation ratio.
4. Insulation Level: Must be suitable for the voltage level of the primary circuit.
5. Environmental Conditions: CTs must be rated for the environmental conditions they will be exposed to, such as temperature, humidity, and pollution levels.
6. Size and Physical Characteristics: The physical size and shape of the CT must be compatible with the installation location and the equipment it is connected to.

In summary, current transformers are vital for the safe and efficient operation of electrical systems, providing a means to measure, control, and protect against electrical faults in high-current applications. Their selection should be based on the specific requirements of the system they will be used in.
Please refer to the product rule book for details.