Circuit Breakers

Results:
Circuit Breakers Results:
Filter Results: -1/10000
Comprehensive
Price Priority
Stock Priority
Image
Part Number
Manufacturer
Description
Availability
Unit Price
Quantity
Operation
IUGN26-1REC5-39339-30-G1
Sensata Technologies
knob
Quantity: 3
Ship Date: 7-12 working days
3+ $181.064
- +
x $181.064
Ext. Price: $543.19
MOQ: 3
Mult: 3
SPQ: 1
W92-X112-10
TE Connectivity
277V 2 none 10A magnetic(hydraulic delay) Control lever panel mount 46.86mm*38.1mm*63.5mm
Quantity: 59
Ship Date: 6-12 working days
1+ $251.3826
- +
x $251.3826
Ext. Price: $251.38
MOQ: 1
Mult: 1
9510G213W4F1Z0C2B9
E-T-A Elektrotechnische Apparate
28V 1 magnetic Push Pull,Plunger panel mount
Quantity: 6
Ship Date: 5-12 working days
1+ $140.0544
3+ $137.9484
5+ $120.708
8+ $105.6195
10+ $103.509
- +
x $140.0544
Ext. Price: $140.05
MOQ: 1
Mult: 1
2C30UL
Altech
250V 480V 2 none 30A Thermomagnetic Press tablet DINRail installation
Quantity: 33
Ship Date: 5-12 working days
Within 1 year
1+ $68.134
5+ $63.5472
10+ $58.695
25+ $55.7655
50+ $52.983
100+ $50.3265
- +
x $68.134
Ext. Price: $68.13
MOQ: 1
Mult: 1
IEG666-1-63F-5.00-91-V
Sensata Technologies
3 5A magnetic(hydraulic delay) Press tablet panel mount 60.38mm(length)*57.53mm(height)
Quantity: 5
Ship Date: 7-9 working days
1+ $182.5091
2+ $174.0767
3+ $162.6368
5+ $121.5035
- +
x $182.5091
Ext. Price: $182.50
MOQ: 1
Mult: 1
SPQ: 1
R21-42-1.00A-B182CV-S
Sensata Technologies
2 250V green 1A magnetic(hydraulic delay) Control lever panel mount 45.47mm(length)*39.62mm(height)
Quantity: 3
Ship Date: 7-9 working days
2+ $71.3337
3+ $57.0078
5+ $51.783
25+ $45.8483
50+ $44.4645
100+ $43.7983
- +
x $71.3337
Ext. Price: $142.66
MOQ: 2
Mult: 1
SPQ: 1
M39019/06-240
Sensata Technologies
3 7.5A knob magnetic mount,panel mount 39.67mm(length)*49.2mm(height)
Quantity: 1
Ship Date: 7-9 working days
1+ $1718.7929
- +
x $1718.7929
Ext. Price: $1718.79
MOQ: 1
Mult: 1
SPQ: 1
W92-X112-30
TE Connectivity
277V 2 none 30A magnetic(hydraulic delay) Control lever panel mount 46.86mm*38.1mm*63.5mm
Quantity: 87
Ship Date: 6-12 working days
1+ $160.2235
5+ $149.7918
- +
x $160.2235
Ext. Price: $160.22
MOQ: 1
Mult: 1
219-4-24237-1
Sensata Technologies
4 magnetic(hydraulic delay) panel mount
Quantity: 1
Ship Date: 7-9 working days
1+ $473.8611
2+ $447.5444
3+ $370.2095
5+ $276.5963
10+ $263.8145
25+ $178.719
50+ $165.9373
- +
x $473.8611
Ext. Price: $473.86
MOQ: 1
Mult: 1
SPQ: 1
229G-3-32086-10
Sensata Technologies
480V 3 none 100A Control lever threaded mounting,panel mount 120.65mm*66.29mm*78.94mm
Quantity: 2
Ship Date: 7-9 working days
1+ $318.7439
2+ $303.9174
- +
x $318.7439
Ext. Price: $318.74
MOQ: 1
Mult: 1
SPQ: 1
IULHK111-1-41-7.50-01
Sensata Technologies
3 7.5A knob magnetic mount,panel mount 64.75mm(length)*63.24mm(height)
Quantity: 6
Ship Date: 7-9 working days
1+ $278.4443
2+ $265.4982
3+ $252.8163
5+ $188.8973
- +
x $278.4443
Ext. Price: $278.44
MOQ: 1
Mult: 1
SPQ: 1
ESX10TB102DC 24 V1 A
E-T-A Elektrotechnische Apparate
24V none 1A DINRail installation,threaded mounting 12.5mm(width)*80mm(height)
Quantity: 12
Ship Date: 6-12 working days
1+ $165.3977
5+ $147.7357
10+ $140.3391
- +
x $165.3977
Ext. Price: $165.39
MOQ: 1
Mult: 1
IULK1-1REC4R-66F-2.50-C-91
Sensata Technologies
80V 250V 1 none 20A magnetic(hydraulic delay) Control lever panel mount 63.25mm(length)*83.45mm(height)
Quantity: 100
Ship Date: 18 weeks
1+ $116.825
3+ $110.6
5+ $82.6375
10+ $78.8625
25+ $53.4625
- +
x $116.825
Ext. Price: $116.82
MOQ: 1
Mult: 1
SPQ: 1
IULK2-38515-30
Sensata Technologies
knob magnetic mount,panel mount 63.24mm(length)*64.75mm(height)
Quantity: 100
Ship Date: 18 weeks
1+ $125.875
3+ $119.175
5+ $89.0625
10+ $84.875
25+ $57.55
- +
x $125.875
Ext. Price: $125.87
MOQ: 1
Mult: 1
SPQ: 1
CMLHPK111-1RS5-34572-250
Sensata Technologies
Quantity: 10
Ship Date: 7-9 working days
2+ $98.0013
5+ $91.5871
- +
x $98.0013
Ext. Price: $196.00
MOQ: 2
Mult: 1
SPQ: 1
M55629/3-442
Sensata Technologies
Sensata Technologies
Quantity: 3
Ship Date: 7-9 working days
2+ $90.0458
- +
x $90.0458
Ext. Price: $180.09
MOQ: 2
Mult: 1
SPQ: 1
IEGHS11-1REG4-62-5.00-G-01-V
Sensata Technologies
2 5A magnetic(hydraulic delay) Control lever panel mount
Quantity: 670
Ship Date: 7-9 working days
3+ $46.4127
9+ $43.3665
30+ $41.287
80+ $39.6983
250+ $38.171
- +
x $46.4127
Ext. Price: $139.23
MOQ: 3
Mult: 1
SPQ: 1
MT1-B-14-712-1-A24-B-J
Carling Technologies
12.5A
Quantity: 3
Ship Date: 6-12 working days
1+ $55.1758
5+ $44.9547
10+ $28.9534
- +
x $55.1758
Ext. Price: $55.17
MOQ: 1
Mult: 1
8-1423673-2
TE Connectivity
Quantity: 20388
Ship Date: 7-9 working days
40+ $1.4378
200+ $1.3662
400+ $1.3325
750+ $1.312
1000+ $1.2813
5000+ $1.1583
- +
x $1.4378
Ext. Price: $57.51
MOQ: 40
Mult: 1
SPQ: 1
203-11-20987-2
Sensata Technologies
2 magnetic Control lever snap-in mounting,snap fit,panel mount
Quantity: 3
Ship Date: 7-9 working days
1+ $364.5069
- +
x $364.5069
Ext. Price: $364.50
MOQ: 1
Mult: 1
SPQ: 1
IULHK12-1RS4-27759-2
Sensata Technologies
magnetic(hydraulic delay) Control lever panel mount
Quantity: 3
Ship Date: 7-9 working days
1+ $206.2905
2+ $196.7639
3+ $183.8338
- +
x $206.2905
Ext. Price: $206.29
MOQ: 1
Mult: 1
SPQ: 1
IEG1111-26543-3-V
Sensata Technologies
4 magnetic(hydraulic delay) Control lever panel mount
Quantity: 7
Ship Date: 7-9 working days
1+ $247.4315
2+ $236.0111
3+ $220.498
5+ $164.7483
- +
x $247.4315
Ext. Price: $247.43
MOQ: 1
Mult: 1
SPQ: 1
IUGN66-2REC4-62-5.00
Sensata Technologies
2 5A magnetic(hydraulic delay) knob panel mount
Quantity: 1
Ship Date: 7-9 working days
1+ $226.025
- +
x $226.025
Ext. Price: $226.02
MOQ: 1
Mult: 1
SPQ: 1
BA2-B0-34-630-121-C
Carling Technologies
80V 277V 2 none 30A magnetic(hydraulic delay) Control lever panel mount 61.44mm*39.62mm*50.8mm
Quantity: 3
Ship Date: 6-12 working days
1+ $90.5554
5+ $75.1272
10+ $67.0281
- +
x $90.5554
Ext. Price: $90.55
MOQ: 1
Mult: 1
FAZ-C10/1
EATON
230V 1 10A 2015 80mm*17.5mm*71mm
Quantity: 83
Ship Date: 6-12 working days
1+ $44.385
5+ $36.535
10+ $35.1662
20+ $34.4483
- +
x $44.385
Ext. Price: $44.38
MOQ: 1
Mult: 1

Circuit Breakers

Circuit breakers are essential electrical safety devices that protect electrical circuits from damage caused by overcurrent conditions, such as short circuits or overloads. They function by interrupting the flow of electricity when the current exceeds a safe threshold, preventing potential fires and damage to electrical equipment.

Definition:
A circuit breaker is an automatically operated electrical switch designed to protect an electrical circuit from damage due to excess current from an overload or a short circuit. Its basic function is to cut off the flow of current when it reaches a predetermined level, which is dangerous.

Function:
1. Overcurrent Protection: Circuit breakers trip or "break" the circuit when the current exceeds the breaker's rating, preventing potential damage.
2. Safety: They provide a means of safely disconnecting the circuit for maintenance or in case of an emergency.
3. Automatic Reset: Many circuit breakers are designed to automatically reset once the overcurrent condition is removed.

Applications:
1. Residential: In homes, circuit breakers are used in the electrical panel to protect individual circuits, such as those for lighting, appliances, and outlets.
2. Commercial: In commercial buildings, they protect larger circuits and equipment, ensuring the safety of the electrical system.
3. Industrial: In industrial settings, circuit breakers are critical for protecting machinery and equipment from electrical faults.
4. Power Distribution: They are used in power distribution systems to prevent overloads and short circuits that could disrupt service.

Selection Criteria:
1. Current Rating: Choose a breaker with a current rating that matches the load it will protect.
2. Voltage Rating: Ensure the breaker is rated for the voltage of the circuit it will be used in.
3. Type of Circuit: Different types of breakers are designed for different applications, such as residential, commercial, or industrial use.
4. Certifications: Look for breakers that meet safety standards and certifications relevant to your region.
5. Size and Space: Consider the physical size of the breaker and the space available in the electrical panel.
6. Cost: While cost is a factor, prioritizing safety and reliability over price is crucial.

In summary, circuit breakers are vital for maintaining the integrity and safety of electrical systems. They are selected based on the specific requirements of the circuit they are designed to protect, ensuring that they can effectively manage and interrupt current flow when necessary.
Please refer to the product rule book for details.