Home > Catalogue > Communication Interface ICs > RS-485/RS-422 Transceivers> GREEN MICRO

RS-485/RS-422 Transceivers

Results:
RS-485/RS-422 Transceivers Results:
Filter Results: -1/9
Comprehensive
Price Priority
Stock Priority
Image
Part Number
Manufacturer
Description
Availability
Unit Price
Quantity
Operation
MAX485ESA
GREEN MICRO
MAX485 used forRS-485/RS-422communication,,。。,EMI,500kbps 。have+4kVESD 。RS-485/RS-422,Level Translators,rightEMI,。
Quantity: 78000
Ship Date: 3-5 working days
24+
100+ $0.0415
2500+ $0.0399
12500+ $0.0392
25000+ $0.0382
- +
x $0.0415
Ext. Price: $4.15
MOQ: 100
Mult: 1
MAX485CSA
GREEN MICRO
MAX485 used forRS-485/RS-422communication,,。。,EMI, 500kbps。have+4kVESD。RS-485/RS-422,Level Translators,rightEMI,。
Quantity: 100000
Ship Date: 3-5 working days
24+
100+ $0.0415
2500+ $0.0399
12500+ $0.0392
25000+ $0.0382
- +
x $0.0415
Ext. Price: $4.15
MOQ: 100
Mult: 1
SP485EEP
GREEN MICRO
SP485EEP used for RS-485/RS-422 communication,,。。, EMI , 500kbps 。have+4kVESD 。, 1/8 , 256 。
Quantity: 3200
Ship Date: 3-5 working days
24+
100+ $0.0525
2000+ $0.0504
10000+ $0.0496
20000+ $0.0483
- +
x $0.0525
Ext. Price: $5.25
MOQ: 100
Mult: 1
SP3485E
GREEN MICRO
SP3485E3.3V、half duplex、Low power consumption,TIA/EIA-485RS-485transceiver。,。,。have1/8load,256。12Mbps。
Quantity: 4000
Ship Date: 3-5 working days
24+
100+ $0.0446
2500+ $0.0428
12500+ $0.0421
25000+ $0.0411
- +
x $0.0446
Ext. Price: $4.46
MOQ: 100
Mult: 1
SP485EEN
GREEN MICRO
SP485EEN used for RS-485/RS-422 communication,,。。, EMI , 500kbps 。have+4kVESD 。, 1/8 , 256 。
Quantity: 1945
In Stock
24+
1+ $0.0612
10+ $0.0504
30+ $0.0418
100+ $0.0346
300+ $0.0338
2500+ $0.0322
- +
x $0.0612
Ext. Price: $0.06
MOQ: 1
Mult: 1
SPQ: 2500
75176
GREEN MICRO
75176 used forRS-485/RS-422communication,,。。,EMI,500kbps 。have+4kVESD。RS-485/RS-422,Level Translators,rightEMI,。
Quantity: 34000
Ship Date: 3-5 working days
24+
100+ $0.0395
2500+ $0.0379
12500+ $0.0373
25000+ $0.0363
- +
x $0.0395
Ext. Price: $3.95
MOQ: 100
Mult: 1
SN65LBC184
GREEN MICRO
SN65LBC184SN75176,。,,。、(),。SN65LBC184400-W()
Quantity: 10000
Ship Date: 3-5 working days
24+
100+ $0.0671
2500+ $0.0644
12500+ $0.0633
25000+ $0.0617
- +
x $0.0671
Ext. Price: $6.71
MOQ: 100
Mult: 1
MAX3485ESA
GREEN MICRO
MAX3485ESA3.3V、half duplex、RS-485transceiver,TIA/EIA-485。MAX3485ESA1/8,256individualMAX3485ESA。12Mbps。MAX3485ESA3.0TO3.6V,、、、。
Quantity: 20000
Ship Date: 3-5 working days
24+
100+ $0.0474
2500+ $0.0455
12500+ $0.0448
25000+ $0.0436
- +
x $0.0474
Ext. Price: $4.74
MOQ: 100
Mult: 1
MAX487ESA
GREEN MICRO
MAX487 ,RS-485andRS-422communication。,±15kV(ESD),。。,EMI,250kbps。
Quantity: 8000
Ship Date: 3-5 working days
24+
100+ $0.0487
2500+ $0.0467
12500+ $0.0459
25000+ $0.0448
- +
x $0.0487
Ext. Price: $4.87
MOQ: 100
Mult: 1

RS-485/RS-422 Transceivers

RS485/RS422 IC Definition:

RS485 and RS422 are communication protocols used for serial data transmission, primarily in industrial and networking applications. They are defined by the Electronic Industries Alliance (EIA) and the Telecommunications Industry Association (TIA). RS485 is a standard for balanced, differential signaling that allows for longer distances and higher noise immunity compared to RS422, which is a single-ended signaling standard.

Function:

1. RS485: It supports multiple devices on a single pair of wires, facilitating a network of up to 32 units (with a total of 32 units including the master). RS485 is capable of data rates up to 10 Mbps over short distances, but this decreases with increasing distance, typically to 100 kbps at 1200 meters.

2. RS422: It allows for point-to-point or multi-drop configurations with up to 10 units on a single pair of wires. RS422 supports data rates of up to 10 Mbps over short distances, similar to RS485, but it is more susceptible to noise and interference due to its single-ended signaling.

Applications:

- Industrial Automation: Control systems, sensors, and actuators in factories.
- Building Automation: Security systems, HVAC controls, and lighting.
- Telecommunications: Modems, routers, and network equipment.
- Transportation: Traffic control systems, vehicle communication.
- Medical Equipment: Patient monitors and diagnostic devices.

Selection Criteria:

1. Distance: Choose RS485 for longer distances and RS422 for shorter ones.
2. Noise Immunity: RS485 is more robust against electrical noise due to its differential signaling.
3. Network Size: RS485 is suitable for larger networks with multiple devices.
4. Cost: RS422 might be less expensive due to simpler hardware requirements.
5. Device Compatibility: Ensure that the ICs are compatible with the devices in your network.
6. Data Rate Requirements: Consider the maximum data rate needed for your application.
7. Environmental Factors: Choose ICs that can operate in the expected environmental conditions, such as temperature and humidity.

When selecting RS485/RS422 ICs, it's crucial to consider the specific requirements of your application, including the physical layout, the number of devices, and the environmental conditions in which the system will operate.
Please refer to the product rule book for details.