Home > Catalogue > Magnetic Components > Pulse Transformers> Triad Magnetics

Pulse Transformers

Results:
Pulse Transformers Results:
Filter Results: -1/9
Comprehensive
Price Priority
Stock Priority
Image
Part Number
Manufacturer
Description
Availability
Unit Price
Quantity
Operation
GDE25-2
Triad Magnetics
1:1:1 Gate Drive 680μH 540Vμs Plugins,D27.9XL26.4MM Through hole mounting 27.94mm*26.42mm*30.48mm
Quantity: 287
Ship Date: 7-12 working days
1+ $16.4736
10+ $14.8398
25+ $14.2297
50+ $13.7829
100+ $13.3485
250+ $12.7928
500+ $12.3863
- +
x $16.4736
Ext. Price: $16.47
MOQ: 1
Mult: 1
SPQ: 1
GDE25-5
Triad Magnetics
1:1.5 Gate Drive 680μH 540Vμs Plugins,D27.9XL26.4MM Through hole mounting 27.94mm*26.42mm*30.48mm
Quantity: 3
Ship Date: 5-12 working days
1+ $12.2705
5+ $11.155
25+ $10.26
50+ $10.0548
100+ $9.5865
250+ $9.387
500+ $9.198
1000+ $9.0195
- +
x $12.2705
Ext. Price: $36.81
MOQ: 3
Mult: 3
GDE25-6
Triad Magnetics
1:1.5:1.5 Gate Drive 680μH 540Vμs Through hole mounting 27.94mm*26.42mm*30.48mm
Quantity: 100
Ship Date: 7-12 working days
1+ $17.1496
10+ $15.4482
25+ $14.8129
50+ $14.3476
100+ $13.8952
250+ $13.3164
500+ $12.8932
- +
x $17.1496
Ext. Price: $17.14
MOQ: 1
Mult: 1
SPQ: 1
GDE25-3
Triad Magnetics
1.5:1 Gate Drive 1.5mH 840Vμs Through hole mounting 27.94mm*26.42mm*30.48mm
Quantity: 159
Ship Date: 7-12 working days
1+ $16.4736
10+ $14.8398
25+ $14.2297
50+ $13.7829
100+ $13.3485
250+ $12.7928
500+ $12.3863
- +
x $16.4736
Ext. Price: $16.47
MOQ: 1
Mult: 1
SPQ: 1
GDE25-4
Triad Magnetics
1.5:1:1 Gate Drive 1.5mH 840Vμs Plugins,D27.9XL26.4MM Through hole mounting 27.94mm*26.42mm*30.48mm
Quantity: 40
Ship Date: 5-12 working days
5+ $13.75
25+ $12.7008
50+ $12.012
100+ $11.676
250+ $11.235
500+ $10.899
1000+ $10.563
- +
x $13.75
Ext. Price: $68.75
MOQ: 5
Mult: 5
GDE25-4-B
Triad Magnetics
1.5:1:1 Gate Drive 1.5mH 840Vμs Through hole mounting 27.94mm*26.42mm*30.48mm
Quantity: 0
Ship Date: 7-12 working days
1+ $20.592
- +
x $20.592
Ext. Price: $20.59
MOQ: 1
Mult: 1
SPQ: 1
GDE25-5-B
Triad Magnetics
1:1.5 Gate Drive 680μH 540Vμs Plugins,D27.9XL26.4MM Through hole mounting 27.94mm*26.42mm*30.48mm
Quantity: 0
Ship Date: 7-12 working days
1+ $20.592
- +
x $20.592
Ext. Price: $20.59
MOQ: 1
Mult: 1
SPQ: 1
GDE25-1
Triad Magnetics
1:1 Gate drive 680μH 540Vμs Plugins,D27.9XL26.4MM Through hole mounting 27.94mm*26.42mm*30.48mm
Quantity: 0
Ship Date: 9-11 working days
4+ $13.31
20+ $13.123
40+ $13.035
125+ $12.826
- +
x $13.31
Ext. Price: $106.48
MOQ: 8
Mult: 1
SPQ: 1
GDE25-6-B
Triad Magnetics
1:1.5:1.5 Gate Drive 680μH 540Vμs Plugins,D27.9XL26.4MM Through hole mounting 27.94mm*26.42mm*30.48mm
Quantity: 0
Ship Date: 7-12 working days
1+ $20.592
- +
x $20.592
Ext. Price: $20.59
MOQ: 1
Mult: 1
SPQ: 1

Pulse Transformers

Pulse transformers are specialized electrical components that are designed to transmit electrical signals, typically in the form of pulses, from one circuit to another while maintaining isolation between the two circuits. They are crucial in various applications where signal integrity and safety are paramount.

Definition:
A pulse transformer is a type of transformer that is optimized for handling pulsed signals rather than continuous or sinusoidal signals. It is characterized by its ability to handle high voltages and currents for short durations, which is essential for applications involving rapid changes in signal levels.

Function:
The primary function of a pulse transformer is to transfer electrical energy from one circuit to another while providing electrical isolation. This isolation is achieved by having separate primary and secondary windings that are magnetically coupled but electrically insulated from each other. Pulse transformers are also used to step up or step down the voltage levels, depending on the turns ratio of the windings.

Applications:
1. High-Voltage Pulse Generation: They are used in devices that require high-voltage pulses, such as in electrostatic precipitators or in medical equipment like defibrillators.
2. Signal Conditioning: In digital communication systems, pulse transformers are used to condition signals for transmission, ensuring that they meet the requirements of the communication channel.
3. Isolation: They provide galvanic isolation between circuits, which is essential for safety in applications where there is a risk of electrical shock or interference between different parts of a system.
4. Testing and Measurement: Pulse transformers are used in high-voltage testing equipment to generate and measure pulsed voltages without the risk of direct electrical contact.

Selection Criteria:
When selecting a pulse transformer, the following criteria should be considered:
1. Voltage Rating: The transformer must be able to handle the peak voltage levels expected in the application.
2. Current Rating: It should be capable of handling the maximum current that will flow through it.
3. Pulse Duration and Frequency: The transformer should be designed to handle the specific pulse duration and repetition rate of the application.
4. Impedance Matching: The transformer's impedance should be matched to the source and load impedances to ensure efficient transfer of energy.
5. Physical Size and Weight: Depending on the application, the size and weight of the transformer may be important factors.
6. Temperature Rating: The transformer should be able to operate within the temperature range of the environment in which it will be used.
7. Safety Standards: The transformer should comply with relevant safety standards and regulations.

In summary, pulse transformers are indispensable in applications that require the transmission of pulsed signals with high voltages and currents, while maintaining electrical isolation for safety and signal integrity. Their selection should be based on a careful consideration of the specific requirements of the application.
Please refer to the product rule book for details.