Home > Catalogue > Circuit Protection > Gas Discharge Tubes (GDT)> PHOENIX CONTACT

Gas Discharge Tubes (GDT)

Results:
Gas Discharge Tubes (GDT) Results:
Filter Results: -1/32
Comprehensive
Price Priority
Stock Priority
Image
Part Number
Manufacturer
Description
Availability
Unit Price
Quantity
Operation
CN-UB-G1
PHOENIX CONTACT
Gas-filled surge arrester CN-UB-G1
Quantity: 77
Ship Date: 7-13 working days
1+ $144.1557
- +
x $144.1557
Ext. Price: $1441.55
MOQ: 10
Mult: 10
2905589
PHOENIX CONTACT
Connecting cable for FLT-ISG-100-EX, length 100 mm.
Quantity: 9
Ship Date: 6-13 working days
1+ $50.226
- +
x $50.226
Ext. Price: $50.22
MOQ: 1
Mult: 1
SPQ: 1
2818203
PHOENIX CONTACT
2 20KA no
Quantity: 1
Ship Date: 6-13 working days
1+ $24.909
- +
x $24.909
Ext. Price: $24.90
MOQ: 1
Mult: 1
SPQ: 1
2905579
PHOENIX CONTACT
2 100KA no
Quantity: 3
Ship Date: 7-12 working days
1+ $409.1672
- +
x $409.1672
Ext. Price: $409.16
MOQ: 1
Mult: 1
SPQ: 1
2905588
PHOENIX CONTACT
SPARK GAP
Quantity: 10
Ship Date: 7-12 working days
1+ $11.687
- +
x $11.687
Ext. Price: $11.68
MOQ: 1
Mult: 1
SPQ: 1
2788919
PHOENIX CONTACT
Phoenix,gas discharge tube,SVP2E-48AC,2 no SMD mount 6mm(length)
Quantity: 1000
Ship Date: 10-20 weeks
10+ $6.7879
100+ $6.7278
- +
x $6.7879
Ext. Price: $67.87
MOQ: 10
Mult: 10
SPQ: 10
2817424
PHOENIX CONTACT
3 35KA
Quantity: 100
Ship Date: 10-20 weeks
1+ $223.5923
10+ $221.6136
- +
x $223.5923
Ext. Price: $223.59
MOQ: 1
Mult: 1
SPQ: 1
2765534
PHOENIX CONTACT
Phoenix,gas discharge tube,SVP2E-110AC,2-Electrode Gas Discharge Tube 110VAC
Quantity: 1000
Ship Date: 10-20 weeks
10+ $6.7879
100+ $6.7278
- +
x $6.7879
Ext. Price: $67.87
MOQ: 10
Mult: 10
SPQ: 10
SVP 2E- 48AC
PHOENIX CONTACT
Gas-filled surge arrester SVP 2E- 48AC
Quantity: 0
Ship Date: 7-13 working days
1+ $79.5211
- +
x $79.5211
Ext. Price: $795.21
MOQ: 10
Mult: 10
SVP 2E-110AC
PHOENIX CONTACT
Gas-filled surge arrester SVP 2E-110AC
Quantity: 0
Ship Date: 7-13 working days
1+ $75.891
- +
x $75.891
Ext. Price: $758.91
MOQ: 10
Mult: 10
2905755
PHOENIX CONTACT
Quantity: 0
Ship Date: 6-13 working days
1+ $10.3385
- +
x $10.3385
Ext. Price: $10.33
MOQ: 1
Mult: 1
SPQ: 1
2905591
PHOENIX CONTACT
Quantity: 0
Ship Date: 6-13 working days
1+ $54.494
- +
x $54.494
Ext. Price: $54.49
MOQ: 1
Mult: 1
SPQ: 1
2905762
PHOENIX CONTACT
Quantity: 0
Ship Date: 6-13 working days
1+ $19.55
- +
x $19.55
Ext. Price: $19.55
MOQ: 1
Mult: 1
SPQ: 1
2905759
PHOENIX CONTACT
Quantity: 0
Ship Date: 6-13 working days
1+ $19.55
- +
x $19.55
Ext. Price: $19.55
MOQ: 1
Mult: 1
SPQ: 1
2905587
PHOENIX CONTACT
Quantity: 0
Ship Date: 6-13 working days
1+ $10.3385
- +
x $10.3385
Ext. Price: $10.33
MOQ: 1
Mult: 1
SPQ: 1
2859709
PHOENIX CONTACT
2 no DINRail installation
Quantity: 0
Ship Date: 7-12 working days
- +
x $
Ext. Price:
MOQ: 1
Mult: 1
SPQ: 1
2905761
PHOENIX CONTACT
Quantity: 0
Ship Date: 6-13 working days
1+ $19.55
- +
x $19.55
Ext. Price: $19.55
MOQ: 1
Mult: 1
SPQ: 1
2905760
PHOENIX CONTACT
Quantity: 0
Ship Date: 6-13 working days
1+ $19.55
- +
x $19.55
Ext. Price: $19.55
MOQ: 1
Mult: 1
SPQ: 1
2905754
PHOENIX CONTACT
Quantity: 0
Ship Date: 6-13 working days
1+ $10.3385
- +
x $10.3385
Ext. Price: $10.33
MOQ: 1
Mult: 1
SPQ: 1
2905756
PHOENIX CONTACT
Quantity: 0
Ship Date: 6-13 working days
1+ $10.3385
- +
x $10.3385
Ext. Price: $10.33
MOQ: 1
Mult: 1
SPQ: 1
2905765
PHOENIX CONTACT
Quantity: 0
Ship Date: 6-13 working days
1+ $19.55
- +
x $19.55
Ext. Price: $19.55
MOQ: 1
Mult: 1
SPQ: 1
2905764
PHOENIX CONTACT
Quantity: 0
Ship Date: 6-13 working days
1+ $19.55
- +
x $19.55
Ext. Price: $19.55
MOQ: 1
Mult: 1
SPQ: 1
2905586
PHOENIX CONTACT
Quantity: 0
Ship Date: 6-13 working days
1+ $10.3385
- +
x $10.3385
Ext. Price: $10.33
MOQ: 1
Mult: 1
SPQ: 1
2905590
PHOENIX CONTACT
Quantity: 0
Ship Date: 6-13 working days
1+ $52.36
- +
x $52.36
Ext. Price: $52.36
MOQ: 1
Mult: 1
SPQ: 1
2905747
PHOENIX CONTACT
Quantity: 0
Ship Date: 6-13 working days
1+ $10.3385
- +
x $10.3385
Ext. Price: $10.33
MOQ: 1
Mult: 1
SPQ: 1

Gas Discharge Tubes (GDT)

Gas Discharge Tubes (GDTs) are a type of overvoltage protection device that operates by using the ionization of gas to conduct electricity. They are designed to protect sensitive electronic equipment from voltage surges, which can be caused by lightning, power line switching, or other electrical disturbances.

Definition:
A Gas Discharge Tube is a passive electronic component that contains two or more electrodes within a gas-filled envelope. When the voltage across the GDT exceeds a certain threshold, the gas ionizes, creating a conductive path that allows the excess voltage to be safely discharged.

Function:
The primary function of a GDT is to clamp the voltage to a safe level by diverting the surge current away from the protected equipment. When the voltage across the GDT is below the ionization threshold, it acts as an open circuit, allowing normal operation of the equipment. Once the voltage exceeds the threshold, the GDT ionizes the gas, becoming a low-impedance path for the surge current to flow, thus protecting the equipment from damage.

Applications:
GDTs are widely used in various applications where overvoltage protection is necessary:
1. Telecommunications equipment, such as telephone exchanges and network infrastructure.
2. Power distribution systems to protect against lightning-induced surges.
3. Industrial control systems to safeguard against voltage spikes.
4. Consumer electronics, like televisions and computers, to protect against power surges.
5. Automotive electronics to protect against transient voltages.

Selection Criteria:
When selecting a GDT, several factors should be considered:
1. Voltage Rating: The GDT should have a continuous voltage rating that is compatible with the system's operating voltage.
2. Surge Current Capability: The GDT must be able to handle the expected surge current without failing.
3. Response Time: The GDT should have a fast response time to effectively protect against fast-rising surges.
4. Recovery Time: After discharging, the GDT should return to its non-conductive state quickly to minimize the impact on normal operation.
5. Physical Size and Mounting: The GDT should be compatible with the available space and mounting requirements of the equipment.
6. Environmental Considerations: The GDT should be suitable for the environmental conditions it will be exposed to, such as temperature and humidity.

In summary, Gas Discharge Tubes are crucial components in the protection of electronic systems from overvoltage events. They are selected based on their ability to handle the specific voltage and current requirements of the application, as well as their physical and environmental compatibility.
Please refer to the product rule book for details.