Contactors

Results:
Contactors Results:
Filter Results: -1/31
Comprehensive
Price Priority
Stock Priority
Image
Part Number
Manufacturer
Description
Availability
Unit Price
Quantity
Operation
ESC440S
hager
230V DINRail installation,threaded mounting
Quantity: 1
Ship Date: 5-10 working days
1+ $283.1683
- +
x $283.1683
Ext. Price: $283.16
MOQ: 1
Mult: 1
ESC225S
hager
230V DINRail installation,threaded mounting
Quantity: 8
Ship Date: 7-13 working days
1+ $123.8901
- +
x $123.8901
Ext. Price: $123.89
MOQ: 1
Mult: 1
ESD425S
hager
24V DINRail installation,threaded mounting
Quantity: 1
Ship Date: 5-10 working days
1+ $187.7393
- +
x $187.7393
Ext. Price: $187.73
MOQ: 1
Mult: 1
ESC465
hager
230V DINRail installation,threaded mounting
Quantity: 1
Ship Date: 5-10 working days
1+ $404.1233
- +
x $404.1233
Ext. Price: $404.12
MOQ: 1
Mult: 1
ESC425S
hager
230V DINRail installation,threaded mounting
Quantity: 4
Ship Date: 7-13 working days
1+ $161.4985
- +
x $161.4985
Ext. Price: $161.49
MOQ: 1
Mult: 1
ESD426
hager
Contactor 25A, 4O, 24V
Quantity: 4
Ship Date: 7-13 working days
1+ $192.0433
- +
x $192.0433
Ext. Price: $192.04
MOQ: 1
Mult: 1
ERD225
hager
Manually operated contactor 25A, 2F, 24V
Quantity: 1
Ship Date: 7-13 working days
1+ $161.8298
- +
x $161.8298
Ext. Price: $161.82
MOQ: 1
Mult: 1
ESC240S
hager
230V DINRail installation,threaded mounting
Quantity: 1
Ship Date: 5-10 working days
1+ $229.6749
- +
x $229.6749
Ext. Price: $229.67
MOQ: 1
Mult: 1
ERD225SDC
hager
Manually operated silent contactor 25A,
Quantity: 0
Ship Date: 7-13 working days
1+ $170.9196
- +
x $170.9196
Ext. Price: $170.91
MOQ: 1
Mult: 1
ESC427
hager
230V DINRail installation,threaded mounting
Quantity: 0
Ship Date: 7-13 working days
1+ $181.9923
- +
x $181.9923
Ext. Price: $181.99
MOQ: 1
Mult: 1
ESD227
hager
24V DINRail installation,threaded mounting
Quantity: 0
Ship Date: 7-13 working days
1+ $169.395
- +
x $169.395
Ext. Price: $169.39
MOQ: 1
Mult: 1
ESD263
hager
24V DINRail installation,threaded mounting
Quantity: 0
Ship Date: 7-13 working days
1+ $308.3262
- +
x $308.3262
Ext. Price: $308.32
MOQ: 1
Mult: 1
ESC340
hager
230V DINRail installation,threaded mounting
Quantity: 0
Ship Date: 7-13 working days
1+ $240.9867
- +
x $240.9867
Ext. Price: $240.98
MOQ: 1
Mult: 1
ESC441
hager
230V DINRail installation,threaded mounting
Quantity: 0
Ship Date: 7-13 working days
1+ $339.857
- +
x $339.857
Ext. Price: $339.85
MOQ: 1
Mult: 1
ESD225
hager
Contactor 25A, 2F, 24V
Quantity: 0
Ship Date: 7-13 working days
1+ $152.7317
- +
x $152.7317
Ext. Price: $152.73
MOQ: 1
Mult: 1
ESC442
hager
230V DINRail installation,threaded mounting
Quantity: 0
Ship Date: 7-13 working days
1+ $414.4506
- +
x $414.4506
Ext. Price: $414.45
MOQ: 1
Mult: 1
ESC263S
hager
230V DINRail installation,threaded mounting
Quantity: 0
Ship Date: 7-13 working days
1+ $327.271
- +
x $327.271
Ext. Price: $327.27
MOQ: 1
Mult: 1
ETC425S
hager
Day-Night Silent Contactor 25A, 4F, 230V
Quantity: 0
Ship Date: 7-13 working days
1+ $301.2922
- +
x $301.2922
Ext. Price: $301.29
MOQ: 1
Mult: 1
ESD440S
hager
24V DINRail installation,threaded mounting
Quantity: 0
Ship Date: 7-13 working days
1+ $352.6227
- +
x $352.6227
Ext. Price: $352.62
MOQ: 1
Mult: 1
ESC464
hager
230V DINRail installation,threaded mounting
Quantity: 0
Ship Date: 7-13 working days
1+ $466.9042
- +
x $466.9042
Ext. Price: $466.90
MOQ: 1
Mult: 1
ESC227
hager
230V DINRail installation,threaded mounting
Quantity: 0
Ship Date: 7-13 working days
1+ $141.6589
- +
x $141.6589
Ext. Price: $141.65
MOQ: 1
Mult: 1
ESC363
hager
230V DINRail installation,threaded mounting
Quantity: 0
Ship Date: 7-13 working days
1+ $337.2192
- +
x $337.2192
Ext. Price: $337.21
MOQ: 1
Mult: 1
ESD463
hager
24V DINRail installation,threaded mounting
Quantity: 0
Ship Date: 7-13 working days
1+ $438.3673
- +
x $438.3673
Ext. Price: $438.36
MOQ: 1
Mult: 1
ESC463S
hager
230V DINRail installation,threaded mounting
Quantity: 0
Ship Date: 7-13 working days
1+ $358.5554
- +
x $358.5554
Ext. Price: $358.55
MOQ: 1
Mult: 1
ERL218
hager
12V
Quantity: 0
Ship Date: 7-13 working days
1+ $167.1647
- +
x $167.1647
Ext. Price: $167.16
MOQ: 1
Mult: 1

Contactors

Contactors are electromechanical devices used in electrical systems to control the flow of power to various loads, such as motors, heaters, and transformers. They are typically employed in industrial and commercial settings where high currents are involved.

Definition:
A contactor is an automatic or semi-automatic electrically operated device used to make, carry, and break currents under normal circuit conditions. It is designed to handle high currents and voltages, often in conjunction with a protective relay system.

Functions:
1. Switching: Contactors are used to switch on and off high-power loads.
2. Protection: They can be integrated with overload and short-circuit protection to safeguard the connected equipment.
3. Control: They can be controlled remotely or through automation systems, allowing for the automation of processes.
4. Interlocking: They can be used to ensure that certain conditions are met before power is supplied to a load.

Applications:
1. Industrial Automation: In factories, contactors control the operation of motors and other machinery.
2. Power Distribution: They are used in power distribution systems to manage the flow of electricity to different parts of a building or facility.
3. HVAC Systems: Contactors are used to control the motors in heating, ventilation, and air conditioning systems.
4. Transportation: In electric vehicles and rail systems, contactors manage the power to the traction motors.

Selection Criteria:
1. Current Rating: The contactor must be rated for the current it will carry.
2. Voltage Rating: It should be suitable for the voltage of the system it is connected to.
3. Duty Cycle: The contactor should be able to handle the required number of operations per hour.
4. Environmental Conditions: Consider the temperature, humidity, and other environmental factors where the contactor will be used.
5. Mounting Style: Choose between panel-mounted, DIN-rail mounted, or other mounting styles based on the application.
6. Coil Voltage: The contactor's coil voltage should match the control circuit voltage.
7. Auxiliary Contacts: Consider the need for additional contacts for control or signaling purposes.
8. Safety Features: Ensure the contactor has built-in safety features like arc suppression and short-circuit protection.

When selecting a contactor, it is important to consider the specific requirements of the application to ensure reliable and efficient operation.
Please refer to the product rule book for details.